12- ENG
D25801
STARTING
1.
Verify the filter screen
is in water inlet of pump.
NOTE:
Cone side faces out.
2.
See How To Use Wand
instructions in this section
and select the correct quick connect nozzle for the
job to be performed
3.
Make sure the ON/OFF switch is in the OFF
position.
4.
Plug the unit into an appropriate outlet
that is
properly installed and grounded in accordance
with all local codes and ordinances. See the
GROUNDING INSTRUCTION paragraph.
ATTENTION: Test GFCI plug before each use.
To test:
a.
Plug GFCI into an appropriate outlet.
b.
Press the reset button.
c.
Press the test button. Red indicator on reset
button should appear.
d.
Press reset button again for use. Do not use
if above test fails.
5.
Connect
water source to pump inlet.
NOTE:
Water source must provide a minimum of 5
gallons per minute at 20 p.s.i.
6.
Connect
high pressure hose to pump outlet.
7.
If applying a chemical or cleaning solution
, see
How To Siphon Chemicals/Cleaning Solvents in
Operation section of this manual.
8.
Turn water source on.
9.
Place the ON-OFF switch in the On position.
10. Depress trigger on gun to start water flow.
NOTE: Stand on a stable surface
and grip
gun/wand firmly with both hands. Expect the
gun to kick when triggered.
11. Release trigger to stop water flow.
SHUTTING DOWN
1.
After each use,
if you have siphoned
chemicals, siphon a bucket of clean water through the chemical hose.
NOTE:
Failure to do so will cause damage to the pump.
2.
Place the ON-OFF switch in the Off position. NOTE:
NEVER turn the
water off with the motor running.
3.
Turn water source off.
4.
Pull trigger on spray gun
to relieve any water pressure in hose or spray
gun.
5.
See Storage section
in this manual for proper storage procedures.
Filter Screen
Water
Source
High Pressure
Hose Hookup
ON/OFF
Switch
GFCI
Plug
Summary of Contents for PCE1700
Page 20: ...20 ENG D25801...
Page 40: ...40 SP D25801 NOTA...