Porter-Cable PCCR701 Instruction Manual Download Page 8

English

6

the battery. Return it to a service center or a collection site 
for  ecycling.

Hot/Cold Pack Delay

When the charger detects a battery that is excessively 
hot or excessively cold, it automatically starts a Hot/Cold 
Pack Delay, suspending charging until the battery has 
normalized. After this happens, the charger automatically 
switches to the Pack Charging mode. This feature ensures 
maximum battery life. The light flashes in the pattern 
indicated on the label.

Leaving the Battery in the Charger

The charger and battery pack can be left connected with 
the LED glowing indefinitely. The charger will keep the 
battery pack fresh and fully charged. This charger features 
an automatic tune-up mode which equals or balances the 
individual cells in the battery pack to allow it to function at 
peak capacity. Battery packs should be tuned up weekly or 
whenever the battery no longer delivers the same amount 
of work. To use the automatic tune-up mode, place the 
battery pack in the charger and leave it for at least 8 hours.

Charger Cleaning Instructions

 

WARNING: 

Shock hazard. Disconnect the radio from 

the AC outlet before cleaning. Dirt and grease may be 
removed from the exterior of the radio using a cloth 
or soft non-metallic brush. Do not use water or any 
cleaning solutions.

Important Charging Notes

1.  Longest life and best performance can be obtained if 

the battery pack is charged when the air temperature is 
between 65 °F and 75 °F (18 ° – 24 °C). DO NOT charge 
the battery pack in an air temperature below +40 °F 
(+4.5 °C), or above +104 °F (+40 °C). This is important 
and will prevent serious damage to the battery pack.

2.  The charger and battery pack may become warm to the 

touch while charging. This is a normal condition, and 
does not indicate a problem. To facilitate the cooling of 
the battery pack after use, avoid placing the charger or 
battery pack in a warm environment such as in a metal 
shed or an uninsulated trailer.

3.  If the battery pack does not charge properly:

a.  Check operation of receptacle by plugging in a lamp 

or other appliance;

b.  Check to see if receptacle is connected to a light 

switch which turns power off when you turn out 
the lights;

c.  Move the charger and battery pack to a location 

where the surrounding air temperature is 
approximately 65 °F – 75 °F (18 ° – 24 °C);

d.  If charging problems persist, take the tool, battery 

pack and charger to your local service center.

4.  The battery pack should be recharged when it fails to 

produce sufficient power on jobs which were easily 
done previously. DO NOT CONTINUE to use under these 
conditions. Follow the charging procedure. You may 

also charge a partially used pack whenever you desire 
with no adverse effect on the battery pack.

5.  Foreign materials of a conductive nature such as, but 

not limited to, grinding dust, metal chips, steel wool, 
aluminum foil, or any buildup of metallic particles 
should be kept away from charger cavities. Unplug the 
charger before attempting to clean.

6.  Do not freeze or immerse the charger in water or any 

other liquid.

Storage Recommendations

1.  The best storage place is one that is cool and dry, away 

from direct sunlight and excess heat or cold.

2.  For long storage, it is recommended to store a fully 

charged battery pack in a cool dry place out of the 
charger for optimal results.

nOTE:

 Battery packs should not be stored completely 

depleted of charge. The battery pack will need to be 
recharged before use.

SAVE THESE INSTRUCTIONS FOR 

FUTURE USE

COMPONENTS (FIG. A)

 

WARNING: 

Never modify the charger, radio or any 

part of it. Damage or personal injury could result.

Refer to Fig. A at the beginning of this manual for a 
complete list of components.

INTENDED USE

This charger / radio is designed for broadcast radio 
reception, to play/stream audio through a wired connection 
to a mobile phone or other audio device, and to charge 
PORTER-CABLE batteries.

DO nOT

 use under wet conditions or in presence of 

flammable liquids or gases.

DO nOT

 let children come into contact with the tool. 

Supervision is required when inexperienced operators use 
this tool.

OPERATION
To Install Coin Cell Battery (Fig. B)

Your radio is equipped with memory capacity in order to 
store the preset time. When the radio is in the OFF position, 
this memory capacity is powered by one coin cell battery 
that is included with the radio. 

nOTE: 

For first time use, remove the protective tab under 

the battery door to activate the coin cell battery.

 

WARNING:

 Danger of explosion if battery is 

incorrectly replaced. When replacing battery, replace 
it with the same or equivalent type CR2032. Observe 
correct polarity (+ and –) when replacing batteries. 
Do not store or carry batteries so that metal objects 
can contact exposed battery terminals.

1.  On the battery door  

 14 

 on the back of the unit, turn 

the screw  

 16 

 counterclockwise to remove. Screw will 

remain captive in the door.

Summary of Contents for PCCR701

Page 1: ...e com ServiceAndSupport ProductRegistration aspx pour enregistrer votre nouveau produit Gracias por elegir PORTER CABLE usted Para registrar su nuevo producto visite www portercable com ServiceAndSupp...

Page 2: ...English English original instructions 1 Fran ais traduction de la notice d instructions originale 10 Espa ol traducido de las instrucciones originales 21...

Page 3: ...or moderate injury Used without word Indicates a safety related message NOTICE Indicates a practice not related to personal injury which if not avoided may result in property damage WARNING Read all...

Page 4: ...ries away from children If the battery compartment does not close securely stop using the product and keep it away from children If you think batteries might have been swallowed or placed inside any p...

Page 5: ...battery pack is not fully charged out of the carton Before using the battery pack and charger read the safety instructions below and then follow charging procedures outlined When ordering replacement...

Page 6: ...th Part 15 of the FCC rules and Industry Canada License exempt RSS standard s Operation is subject to the following two conditions This device may not cause harmful interference and This device must a...

Page 7: ...ng This will reduce the risk of electric shock Removing the battery pack will not reduce this risk NEVER attempt to connect 2 chargers together The charger is designed to operate on standard 120V hous...

Page 8: ...sist take the tool battery pack and charger to your local service center 4 The battery pack should be recharged when it fails to produce sufficient power on jobs which were easily done previously DO N...

Page 9: ...n the radio OFF Volume Adjustment 1 Rotate the ON OFF Volume dial 1 clockwise to increase the volume 2 To decrease the volume rotate the ON OFF Volume dial 1 counter clockwise NOTE If the battery is a...

Page 10: ...io will not automatically switch to AUX Mode when an input source is detected The mode button 2 needs to be set to the AU function Maintenance Cleaning WARNING Blow dirt and dust out of all air vents...

Page 11: ...list of service centers or call the PORTER CABLE Customer Care Center at 888 848 5175 PROBLEM POSSIBLE CAUSE POSSIBLE SOLUTION Unit will not turn ON Battery pack not installed properly Battery pack no...

Page 12: ...dication de recharge 13 Port de bloc piles 20V max 14 Porte de pile pi ce de monnaie 15 Jack auxiliaire Fig A 1 8 8 5 4 6 3 2 7 13 11 11 14 10 12 9 D finitions symboles et termes d alarmes s curit Ces...

Page 13: ...PL TEMENT DANS LE R CEPTACLE NE PAS SE SERVIR DE CETTE PRISE SI LA FICHE DE L ACCESSOIRE NE S INS RE PAS COMPL TEMENT DANS LE R CEPTACLE DANGER DANGER DE BR LURE CHIMIQUE NE PAS ING RER LA PILE Ce pro...

Page 14: ...utilis e une chute de tension se produit dans les fils Plus la rallonge est longue plus grande est la chute de tension Le r sultat est qu une tension r duite est livr e la radio chargeur ou l outil br...

Page 15: ...rter des blocs piles comporte des risques d incendie car les bornes des piles pourraient entrer par inadvertance en contact avec des objets conducteurs tels que cl s pi ces de monnaie outils ou autres...

Page 16: ...embler de fa on incorrecte comporte des risques de chocs lectriques d lectrocution et d incendie D brancher le chargeur du secteur avant tout entretien Cela r duira tout risque de chocs lectriques Le...

Page 17: ...par licence Toute autre marque de commerce et appellation commerciale reste la propri t de leurs propri taires respectifs Ce produit est conforme ces standards lorsqu il est utilis avec un cordon de...

Page 18: ...ards d aluminium ou toute accumulation de particules conductrices devraient tre loign es des ouvertures du chargeur D brancher le chargeur avant de le nettoyer 6 Ne pas congeler ou immerger le chargeu...

Page 19: ...ton ON OFF une seconde fois R glage du volume 1 Pour augmenter le volume tourner le bouton de volume ON OFF en sens horaire 2 Pour r duire le volume tourner le bouton ON OFF 1 en sens antihoraire REMA...

Page 20: ...eur une troisi me fois REMARQUE Si aucun bouton n est actionn durant 5 secondes le mode de programmation sera annul et l appareil m morisera le nouveau r glage Remarques importantes sur la radio 1 La...

Page 21: ...l gaux particuliers et vous pouvez avoir d autres droits qui varient d une province ou d un tat l autre En plus la garantie les outils PORTER CABLE sont couverts par notre ENTRETIEN GRATUIT DURANT 1 A...

Page 22: ...roduit fait enclencher maintes reprises le disjoncteur cessez imm diatement l utilisation et faites le r parer par un centre de services PORTER CABLE autoris Faites remplacer le cordon ou l interrupte...

Page 23: ...erto de bater a 20v Max 14 Puerta de bater a de celda de moneda 15 Puerto auxiliar Definiciones S mbolos y palabras de alerta de seguridad Este manual de instrucciones utiliza los siguientes s mbolos...

Page 24: ...COMPLETAMENTE PELIGRO NO INGIERA LA BATER A PELIGRO DE QUEMADURA QU MICA Este producto contiene una bater a de celda de moneda bot n Si se ingiere la bater a de celda de moneda bot n puede causar quem...

Page 25: ...curre una ca da de voltaje Mientras mayor sea el cable mayor ser la ca da de voltaje Esto resulta en que se suministre menos voltaje al Cargador Radio o herramienta e incrementa la cantidad de extracc...

Page 26: ...cajones etc junto con clavos tornillos y llaves etc sueltos El transporte de bater as puede causar incendios si sus terminales inadvertidamente entran en contacto con materiales conductores como llave...

Page 27: ...o de servicio autorizado No desarme el cargador ll velo a un centro de servicio autorizado cuando deba ser reparado Si es reensamblado incorrectamente puede causar descargas el ctricas electrocuci n o...

Page 28: ...Las se ales de radiofrecuencia de onda corta de un dispositivo Bluetooth pueden afectar el funcionamiento de otros dispositivos m dicos y electr nicos como marcapasos o aud fonos NOTA La marca denomin...

Page 29: ...ebabas de metal lana de acero papel aluminio o cualquier acumulaci n de part culas met licas se deben mantener alejados de las cavidades del cargador Desconecte el cargador antes de intentar limpiarlo...

Page 30: ...Para operar como un producto inal mbrico inserte una bater a PORTER CABLE 20v Max no incluida en el puerto de la bater a 13 Aseg rese que la bater a est completamente asentada 1 Para encender el radi...

Page 31: ...otros botones de memoria Bot n de ecualizador Para ajustar los bajos y agudos 1 Presione el bot n de ecualizador 6 una vez El ecualizador de bajos aparecer en la pantalla LCD 5 2 Gire la perilla ON OF...

Page 32: ...incia a otra Adem s de la garant a las herramientas PORTER CABLE est n cubiertas por nuestro SERVICIO GRATUITO DE 1 A O PORTER CABLE conservar la herramienta y reemplazar las partes desgastadas causad...

Page 33: ...e repetidamente el interruptor de circuito descontin e el uso de inmediato y pida que se le d servicio en un centro de servicio PORTER CABLE autorizado Pida que el cable o interruptor sea reemplazado...

Page 34: ...t a workload is 20 volts Measured under a workload nominal voltage is 18 La tension initiale maximale du bloc piles mesur e sans charge de travail est de 20 volts La tension nominale est de 18 El m xi...

Reviews: