ON/OFF
lights up red.
Power supply/domestic connection is off.
Vehicle lights up red.
Control unit is off.
Reset is off.
The vehicle charging system is faulty.
The charging process is interrupted.
e
End the charging process at the vehicle and disconnect the
vehicle cable from the vehicle charge port.
e
Disconnect the charger from the mains supply and
reconnect it after 60 seconds.
e
Starting charging
f
Refer to chapter “Starting charging” on page 29.
e
If the fault persists, have the vehicle checked by a qualified
specialist workshop/Porsche partner.
ON/OFF
lights up red.
Power supply/domestic connection flashes
red.
Vehicle
is
off.
Control unit is off.
Reset is off.
There is overvoltage in the charging
infrastructure of the power supply/domestic
connection.
The charging process is interrupted.
e
Disconnect the charger from the mains supply and
reconnect it after 60 seconds.
e
If the fault persists, have the power supply/domestic
connection checked by a qualified electrician.
ON/OFF
lights up red.
Power supply/domestic connection is off.
Vehicle
is
off.
Control unit lights up red.
Reset is off.
The control unit has a technical fault.
The charging process is interrupted.
e
Disconnect the charger from the mains supply and
reconnect it after 60 seconds.
e
If the fault persists, have the control unit checked by a
qualified specialist workshop/Porsche partner.
ON/OFF
lights up red.
Power supply/domestic connection is off.
Vehicle
is
off.
Control unit flashes red.
Reset is off.
The control unit has a technical fault (self-
test failed)
The charging process is interrupted.
e
Disconnect the charger from the mains supply and
reconnect it after 60 seconds.
e
If the fault persists, have the control unit checked by a
qualified specialist workshop/Porsche partner.
ON/OFF
lights up red.
Power supply/domestic connection lights up
red.
Vehicle lights up red.
Control unit is off.
Reset is off.
The charging infrastructure of power supply/
domestic connection is insufficient:
The protective conductor is interrupted or
not present.
Protective conductor monitoring has
interrupted the charging process.
e
Only
non-earthed
mains supply systems (e.g. IT networks):
If necessary, charge the vehicle with protective conductor
monitoring deactivated.
f
Refer to chapter “Deactivating protective conductor
monitoring” on page 29.
e
Only
earthed
mains supply systems: Have the control unit
checked by a qualified specialist workshop/Porsche
partner. Have the power supply/domestic connection
checked by a qualified electrician.