03
Maintenance, Self-diagnosis
944
Testing the Hall generator's power supply
Disconnect the Hall generator's connector.
Ignition on
36
A voltage of 12 Volt +- 1 V must be
measurable between pin 1 (positive) and pin
3
(negative). If this is not the case, check the
wiring with reference to the circuit diagram.
Error code 1141
Error code 1141 draws attention to an error
in
the area of the DME control unit. If this error
code appears, the DME control unit must be
replaced.