
944
Maintenance, Self-diagnosis
03
Troubleshooting
Diagnosis using the tester can refer only to
the error path, but not to a defective
component.
Note:
Before troubleshooting, the entire error
memory must be read out.
Error code 1111
The supply voltage is too low
< 10 V or too high > 16 V.
Possible causes for too low a supply
voltage:
Battery exhausted
Poor contact on the grounding strap
Poor contact on the control unit
A defective regulator may be the cause
of
too high a supply voltage.
Troubleshooting
Printed in Germany - XVI, 1987
03 - 19
Summary of Contents for 1989 944 S2
Page 24: ...03 944 03 12 Blank page...
Page 26: ...03 944 03 14 Blank page...
Page 28: ...03 944 03 16 Blank Page...
Page 42: ...03 944 03 30 Blank page...
Page 52: ...10 944 10 0100 Blank page...
Page 68: ...13 944 This page are missing or blank in the book 13 104 Blank...
Page 70: ...15 944 15 100 Blank page...
Page 88: ...15 944 This page are missing or blank in the book 15 114 Blank page...
Page 98: ...15 944 15 124 Blank page...
Page 112: ...20 944 20 100 Blank Page...
Page 116: ...24 944 24 100 Blank Page...
Page 124: ...26 944 26 100 Blank Page...
Page 126: ...28 944 28 100 Blank Page...
Page 134: ...DME Diagnosis Troubleshooting Dr Ing h c F Porsche Aktiengesellschaft...