Value

Description

255

Disabled (Default)

0 — 100 °C

Temperatur Trigger High Value (Parameter Number 10, Parameter Size 1) Needs parameter ?1 to be set. 

Sets the temperature High value, if the measurement is higher than this value, Basic ON is sent in 

temperature association group(2)

Value

Description

255

Disabled (Default)

0 — 100 °C

Command Classes

Supported Command Classes

Basic (version 1)

Battery (version 1)

Wake Up (version 2)

Association (version 2)

Version (version 1)

Binary Sensor (version 2)

Configuration (version 1)

Alarm (version 3)

Manufacturer Specific (version 1)

Multilevel Sensor (version 5)

Technical Data

(c) 2012 Z-Wave Europe GmbH, Goldbachstr. 13, 09337 Hohenstein-Ernstthal, Germany, All rights reserved, www.zwaveeurope.com - pp 7 

Summary of Contents for POP_004308

Page 1: ...equency of 868 42 MHz to realize a very stable and secure communication Each message is reconfirmed two way communication and every mains powered node can act as a repeater for other nodes meshed netw...

Page 2: ...s along with a modern design It is easy to install and easy for professional installers to open for cleaning A lock prevents the installation of the device without battery The automatic self calibrati...

Page 3: ...ce needs to join an existing wireless network to communicate with the devices of this network This process is called Inclusion Devices can also leave a network This process is called Exclusion Both pr...

Page 4: ...e current status of battery capacity to the user s controller Self Protection Mode If the detector is removed from bracket the detector will send an alarm type smoke alarm level 0xFF to the Z Wave Int...

Page 5: ...n groups and they are always related to certain events e g button pressed sensor triggers In case the event happens all devices stored in the respective association group will receive a common wireles...

Page 6: ...5 At High send OFF Inverts Switching Command on Association Group 4 Smoke Parameter Number 7 Parameter Size 1 Value Description 0 on Smoke send ON Default 255 on Smoke send OFF Send SensorBinary Repor...

Page 7: ...iation group 2 Value Description 255 Disabled Default 0 100 C Command Classes Supported Command Classes Basic version 1 Battery version 1 Wake Up version 2 Association version 2 Version version 1 Bina...

Page 8: ...cess of removing Z Wave devices from the network Association is a control relationship between a controlling device and a controlled device Wakeup Notification is a special wireless message issued by...

Reviews: