Exclusion, Inclusion are confirmed by hitting the programm button for 1 sec when the the sensor is removed
from the mounting ring and the tamper switch is released.
Operating the device
Power-on Mode: 1) Install the battery into the module 2) Close the bracket 3) the detector will take 2 to 4
sec. and emit a beep to confirm and start the burglar system. The detector will alarm once remove the
bracket.
Stand-by Mode: The red LED flashes one time every 334 seconds.
Alarm Mode (It is the status when the alarm is triggered.): If a certain density of smoke is detected, an
audible alarm with 3 beeps, break and 3 beeps will occure. The red LED will flash continuously and rapidly.
Meanwhile, the smoke detector will send an alarm report (type: smoke alarm, state: alarm) to the user’s
controller and also the detector will send an alarm report (type: smoke alarm, state: No alarm).
Error Mode: If the smoke detector beeps three times and yellow LED flashes three times, it indicates the
smoke detector is not working properly. Please require to repair or service.
Low battery warning Mode: The yellow LED will flash once every 43 seconds with a short “beep” sound.
Testing Mode: Test the alarm weekly by pushing the test switch for about 3 sec. until there are 3 beeps and
red LED light on continuously. Then, the smoke detector will send an alarm report (type: smoke alarm, state:
alarm) to the user’s controller and also the dectecor will send an alarm report (type: smoke alarm, state: No
alarm). Please note if the detector beeps three times and yellow LED flashes three times, it indicates the
detector is not working properly. Please require to repair or service.
Battery Power indicator: The detector will report the current status of battery capacity to the user’s
controller.
Self-Protection Mode: If the detector is removed from bracket, the detector will send an alarm (type:smoke
alarm, level:0xFF) to the Z-Wave Interface Controller, and the yellow LED will flash continuously and the
detector will sound.
Silence Mode: The user could press the test switch to get into silence mode to turn off the alarm
temporarily. The silence function will automatically turn into normal operation after 10 minutes if the smoke
concentration around the detector is still at alarming level.
Wakeup Intervals - how to communicate with the device?
W
This device is battery operated and turned into deep sleep state most of the time to save battery
life time. Communication with the device is limited. In order to communicate with the device, a static
controller C is needed in the network. This controller will maintain a mailbox for the battery operated devices
and store commands that can not be received during deep sleep state. Without such a controller,
communication may become impossible and/or the battery life time is significantly decreased.
This device will wakeup regularly and announce the wakeup state by sending out a so called Wakeup
Notification. The controller can then empty the mailbox. Therefore, the device needs to be configured with
the desired wakeup interval and the node ID of the controller. If the device was included by a static
controller this controller will usually perform all necessary configurations. The wakeup interval is a tradeoff
between maximal battery life time and the desired responses of the device.
A wakeup is performed hitting the programm button for 1 sec when the sensor is not removed from the
mounting ring and the tamper switch is not released.
(c) 2012 Z-Wave Europe GmbH, Goldbachstr. 13, 09337 Hohenstein-Ernstthal, Germany, All rights reserved, www.zwaveeurope.com - pp 4