Exclusion, Inclusion are confirmed by hitting the programm button for 1 sec when the the sensor is removed 

from the mounting ring and the tamper switch is released.

Operating the device

Power-on Mode: 1) Install the battery into the module 2) Close the bracket 3) the detector will take 2 to 4 

sec. and emit a beep to confirm and start the burglar system. The detector will alarm once remove the 

bracket.

Stand-by Mode: The red LED flashes one time every 334 seconds.

Alarm Mode (It is the status when the alarm is triggered.): If a certain density of smoke is detected, an 

audible alarm with 3 beeps, break and 3 beeps will occure. The red LED will flash continuously and rapidly. 

Meanwhile, the smoke detector will send an alarm report (type: smoke alarm, state: alarm) to the user’s 

controller and also the detector will send an alarm report (type: smoke alarm, state: No alarm).

Error Mode: If the smoke detector beeps three times and yellow LED flashes three times, it indicates the 

smoke detector is not working properly. Please require to repair or service.

Low battery warning Mode: The yellow LED will flash once every 43 seconds with a short “beep” sound.

Testing Mode: Test the alarm weekly by pushing the test switch for about 3 sec. until there are 3 beeps and 

red LED light on continuously. Then, the smoke detector will send an alarm report (type: smoke alarm, state: 

alarm) to the user’s controller and also the dectecor will send an alarm report (type: smoke alarm, state: No 

alarm). Please note if the detector beeps three times and yellow LED flashes three times, it indicates the 

detector is not working properly. Please require to repair or service.

Battery Power indicator: The detector will report the current status of battery capacity to the user’s 

controller.

Self-Protection Mode: If the detector is removed from bracket, the detector will send an alarm (type:smoke 

alarm, level:0xFF) to the Z-Wave Interface Controller, and the yellow LED will flash continuously and the 

detector will sound.

Silence Mode: The user could press the test switch to get into silence mode to turn off the alarm 

temporarily. The silence function will automatically turn into normal operation after 10 minutes if the smoke 

concentration around the detector is still at alarming level.

Wakeup Intervals - how to communicate with the device?

W

 This device is battery operated and turned into deep sleep state most of the time to save battery 

life time. Communication with the device is limited. In order to communicate with the device, a static 

controller C is needed in the network. This controller will maintain a mailbox for the battery operated devices 

and store commands that can not be received during deep sleep state. Without such a controller, 

communication may become impossible and/or the battery life time is significantly decreased.

This device will wakeup regularly and announce the wakeup state by sending out a so called Wakeup 

Notification. The controller can then empty the mailbox. Therefore, the device needs to be configured with 

the desired wakeup interval and the node ID of the controller. If the device was included by a static 

controller this controller will usually perform all necessary configurations. The wakeup interval is a tradeoff 

between maximal battery life time and the desired responses of the device.

A wakeup is performed hitting the programm button for 1 sec when the sensor is not removed from the 

mounting ring and the tamper switch is not released.

(c) 2012 Z-Wave Europe GmbH, Goldbachstr. 13, 09337 Hohenstein-Ernstthal, Germany, All rights reserved, www.zwaveeurope.com - pp 4 

Summary of Contents for POP_004308

Page 1: ...equency of 868 42 MHz to realize a very stable and secure communication Each message is reconfirmed two way communication and every mains powered node can act as a repeater for other nodes meshed netw...

Page 2: ...s along with a modern design It is easy to install and easy for professional installers to open for cleaning A lock prevents the installation of the device without battery The automatic self calibrati...

Page 3: ...ce needs to join an existing wireless network to communicate with the devices of this network This process is called Inclusion Devices can also leave a network This process is called Exclusion Both pr...

Page 4: ...e current status of battery capacity to the user s controller Self Protection Mode If the detector is removed from bracket the detector will send an alarm type smoke alarm level 0xFF to the Z Wave Int...

Page 5: ...n groups and they are always related to certain events e g button pressed sensor triggers In case the event happens all devices stored in the respective association group will receive a common wireles...

Page 6: ...5 At High send OFF Inverts Switching Command on Association Group 4 Smoke Parameter Number 7 Parameter Size 1 Value Description 0 on Smoke send ON Default 255 on Smoke send OFF Send SensorBinary Repor...

Page 7: ...iation group 2 Value Description 255 Disabled Default 0 100 C Command Classes Supported Command Classes Basic version 1 Battery version 1 Wake Up version 2 Association version 2 Version version 1 Bina...

Page 8: ...cess of removing Z Wave devices from the network Association is a control relationship between a controlling device and a controlled device Wakeup Notification is a special wireless message issued by...

Reviews: