![Pop NUT PNT800A Maintenance Manual Download Page 8](http://html.mh-extra.com/html/pop/nut-pnt800a/nut-pnt800a_maintenance-manual_1579648008.webp)
Page 8 Emhart Teknologies - 50 Shelton Technology Center, Shelton CT 06484 - Tel. (203) 924-9341 - Fax (800) 225-5614
Tool Set Up
1. Check that the correct Nosepiece and Mandrel are fitted for the POP Nut.
Adjust the protruding length of the Mandrel. (Refer to “Maintenance and Testing”
section B).
2. The thread type of the compressed air supply coupling is NPT 1/4.
Connect a joint or coupler of thread type NPT 1/4 to supply compressed air.
(The Coupler and Joint are not provided.)
3. An air filter, regulator and lubricator should be fitted in the air line between the
compressor and the tool, within 3m (6 ft) of the tool. Adjust the supply pressure and
the drip volume of the lubricator oil.
•
Compressed air pressure: 0.5-0.6 MPa. (72.5-87 psi)
•
Oil drip volume from the lubricator: 1-2 drops/ 20 nuts fastened
WARNING!
Use an air hose with a rating of 1.0 MPa (145 psi / 10 bar) or greater maximum ordinary
operating pressure. Also make sure the hose material is suitable for the operating
environment (i.e. oil proof, wear and abrasion resistance etc.).
*For details, refer to a hose manufacturer's catalog.
Coupler (Plug)
Thread size NPT 1/4
Regulator
I.D. 6.5mm
(1/4”) Min.
Not attached
Hose
Compressor
Air filter
Lubricator
Figure 4-1
Coupler (Socket)
3m (6ft) Max.