![Pop NUT PNT800A Maintenance Manual Download Page 26](http://html.mh-extra.com/html/pop/nut-pnt800a/nut-pnt800a_maintenance-manual_1579648026.webp)
Page 26 Emhart Teknologies - 50 Shelton Technology Center, Shelton CT 06484 - Tel. (203) 924-9341 - Fax (800) 225-5614
c) Use a cross-head screwdriver to remove the 4 truss machine screws on the Air Chamber
(Figure 7-15).
d) Stand the tool with the Air Chamber uppermost and lift the Air Chamber off. Pull the Air
Piston assembly and the Tube out (Figure 7-16).
e) Dispose of the old hydraulic oil from the handle in a proper waste oil container.
f) Pour the new hydraulic oil into the bore of the handle (Figure 7-17).
g) Pour the oil in until its surface is level with the backup ring (Figure 7-18).
Figure 7-14
Scale
Lock screw (1.5 mm hex wrench)
Lock screw
(Never loosen)
Control Knob
End of the Control Nut
Control Nut
(Set the position to 10mm)
Truss screw (x 4)
Air Chamber
Tube
Air Piston assembly
Oil
Oil
Penta seal
Back up ring
Figure 7-18
Figure 7-17
Figure 7-16
Figure 7-15
Handle