19
6. LED INDICATOR LIGHT
7. VOLTAGE CONVERSION
Always double-check the voltage of your power source. Connection to improper voltage
can: a) cause severe damage/harm, or b) cause lights and screen to power on without
system function.
All service should only be attempted by a person with appropriate electrical skills, with
all equipment disconnected from power.
The is shipped from the factory with a 240 VAC configuration. If 120VAC is needed,
move the internal jumpers as shown below. If unsure, seek professional advice.
This set of terminal screws can be located inside of the Control Module, and accessed
by removing the six screws from the Control Module's aluminum base. The factory
voltage setting is the 240V configuration, with a jumper clip inserted between the
second and third terminals. The Control Module can be made to accept 110V by
reconfiguring the jumper clips as shown above left, with two jumper clips instead
connecting the first and second terminals, and the third and fourth terminals.