31
6. Maintenance and servicing
7. Repairs
In the event of a problem, the heat pump’s screen displays a fault symbol
instead of temperature indi-
cations. Please consult the table opposite to find the possible causes of a fault and the actions to be taken.
Fault code examples:
7.1 Breakdowns and faults
WARNING: Under normal conditions, a suitable heat pump can heat the water in a swimming
pool by 1°C to 2°C per day. It is therefore quite normal to not feel any temperature difference in
the system when the heat pump is working.
A heated pool must be covered to avoid any loss of heat.
7.2
Advanced status values settings
WARNING :
This is to facilitate maintenance and future repairs.
Only an experienced professional is authorized to modify the default parameters.
WARNING :
Any modification of the parameters reserved automatically results in the cancellation of the
guarantee.
System settings can be checked and changed using the remote control by following the steps below
Step 1:
Press the button
until the icon
flashes to
enter the general heat pump settings.
Step 2:
Press the arrow
to enter the password 168.
Step 3:
enter the correct value using the
and
but-
tons, then validate with the button
Step 4:
Scroll through the codes of the main parameters
using the
and
buttons.
Step 5:
Press the button
to enter the desired setting.
Step 6:
Modify the desired value with the
and
buttons.
Step 7:
Press the button
to validate the value change,
then long press
to return to the main menu.