JUSTDOSING UNO - DUO - REDOX - DUO REDOX - PAPI004051MULTI1 - FR/EN/ES/DE - Rev.05.16
7
3
ACCESSORIES
Put the saddle for the disinfecting injection on the pipe side pool after the filter. Direct the opening
upward. Mark then drill the pipe. Raise with some Teflon the injection connector on the saddle.
Connect the suction strainer to the pH pump with a part of the supplied pipe. Respect the sense of
arrows representing on the top of the pH pump.
Connect the exit of the pump to the injection connector with the rest of the supplied pipe.
Connect the pump to the controller box (Only for Duo model).
Duo model in addition
PH REGULATION ACCESSORIES
Put the first saddle at the middle of the pipe of a minimal length of 40 cm, horizontally. Direct the
opening upward. Mark then drill the pipe. Rise with some Teflon the probe-holder on the saddle.
Put the second saddle at the middle of the horizontal pipe of a minimal length of 50 cm from the first.
Direct the opening upward. Mark, then drill the pipe. Mount everything on the pipe collar. The injection
connector should be as close as possible to the water pushing in to the pool.
Connect the suction strainer of the pH pump with a part of the tubing supplied. Respect the sense of
arrows representing on the top of the pH pump.
Connect the exit of the pH pump to the injection connector with the rest of the supplied pipe.
Connect the pump to the controller box.
2
1
2
3
4
1
2
3
4