5)
SWITCH OFF THE DRIVE!
Unscrew and remove the casing
cover and clean the casing inside.
Mount cover again. . Locking torque
casing screws: 12 Nm
(up to cover charge number 08/13 = 15
Nm)
6)
Lubricate the hose. Switch on the
drive and insert the hose into the
opening of the casing.
7)
The rotating pump pulls in the pump
hose. When the hose appears
approx. 30 mm on the other side of
the casing switch the drive off again.
8)
Put the clamping ring onto the hose as
shown above. Approx. 5 - 10 mm of
the hose should stick out of the ring.
Screws