PONNDORF Gerätetechnik GmbH
Leipziger Strasse 374
D - 34123 Kassel
Operation manual
Hose Pump type
P_high pressure 65
Page 18 of 26
Version 002_GB / 05.2017
Hose pumps are positive displacement pumps which must not convey
against closed fittings (e.g. valves). In case of exceeding the maximum
permissible pressure, the pumps or other parts of the facility can be
damaged. Therefore a protection against pressure exceedance must be
integrated in the pipework on the discharge side (e.g. an overflow valve or
a burst disk).
When using overflow valves or burst disks it must be observed that the
overpressure always will be discharged in a safe direction.
I.e., neither people nor tangible assets may be endangered because of
emissions of the pumping medium.
If flammable liquids or gases may leak, the affected area of emission must
be free of ignition sources !
6.4 Installing / changing the pump hose
The assembly of the pump hose is described on the pages 20 - 23.
This description is material to following cases:
Case
Situation
Necessary work
steps
Delivery of a new hose pump
Pump hose is not built in yet
(standard!) and has to be installed
Chapter 6.5,
Steps 6) to 13)
Pump must be put out of
operation over a longer
period (> 5 days)
Pump hose must be dismantled
Chapter 6.5,
Steps 1) to 4)
Pump should be reactivated
after a longer period
Pump hose must be installed
Chapter 6.5,
Steps 6) to 13)
Hose damage / leakage
Pump hose must be dismantled
and must be replaced by a new
hose
Chapter 6.5,
Steps 1) to 13)
Remove power from the pump by removing the main fuses before doing
any maintenance operations!