TROUBLESHOOTING
REPLACEMENT PARTS: FP2450/3050/3950
(NOTE: THESE ARE THE MOST USED)
Problem
Solution
Check that there are no kinks in the connected tubes
Check that the pump is correctly powered.
The pump is provided with SmartMAG® motor protection. If there is lack of
water or the impeller is blocked the pump recognizes the problem and turns off
and attempts to restart. After 5 restart attempts in the space of 1-minute,
the pump turns off completely. In this case unplug the pump from the electrical
outlet and remove the cause of the problem. After adding water or clearing the
blocked impeller plug the pump back in which will reset the SmartMAG® and the
pump will resume working.
DESCRIPTION
Impeller with O-ring
Insufficient water
coming out of
the pump
Volute with screws
Hose adapter for hoses 38-32-25 mm
Check that the pump intake is clean and without any obstructions
The pump stops
working
Lack of water
or
blocked impeller
No.
1
2
3
*Component subject to wear and tear
WAT E R G A R D E N I N G T O T H E M A X
2
3
1
Make sure that the water level is not too low. The pump must be completely
submerged in water to operate correctly.
Check that the impeller doesn’t have any obstructions
Check that the pump is correctly powered.
WAT E R G A R D E N I N G T O T H E M A X