Operating manual liquid ring vacuum pumps TRVK - TRSK
9
4.3 - PUMP MODELS AND TABLES FOR MATERIAL OF CONSTRUCTION
On the pump nameplate are printed the pump serial number, the year of manufacture and the pump model. Refer to the
following example for understanding the coding of the pump model.
Every letter or number in the pump model designation has a specific meaning relating to the pump design.
Example of pump model number:
T R V K 3003 / 1 - B / F
T
Manufacturer POMPETRAVAINI
…3
Performance project number
R
Liquid ring pump
1
Mechanical project number
V
V = Single stage pump with high vacuum
S = Single stage pump with medium vacuum
B
B = Shaft sealing by stuffing box
C = Shaft sealing by mechanical seal
K
Revision of hydraulic design
F
Material of construction
300…
Ø Flange size (mm)
For additional details regarding standard or special materials contact POMPETRAVAINI.
5 - UNCRATING, LIFTING AND MOVING INSTRUCTIONS
Upon receipt verify that the material received is in exact compliance with that listed on the packing slip.
When uncrating follow the instructions listed below:
- check for visible damages on the crate that could have occurred during transport
- carefully remove the packaging material
- check that pump/or accessories such as tanks, piping, valves, etc. are free from visible markings such as dents and
damage which may have occurred during transportation
- in the event of damage, report this immediately to the transport company and to POMPETRAVAINI's customer service
department.
Take immediate actions to dispose of eventual packaging parts that may generate injuries or risks (for
example edges, nails, splinters, etc.) and of materials subjected to controlled and differentiate disposal
(for example plastic, cartoon, polystyrene materials, etc.) according to the laws into force and to a safe
local environment management. according to the laws into force and to a safe local environment
management.
ATT.: If the pump will be stored, as foreseen in our Operating Manuals, we recommend a proper care to
avoid oil dropping on the ground.
The pump or assembly must
ALWAYS
be moved and transported in the horizontal position.
Prior to moving the unit find the following:
- total weight
- centre of gravity
- maximum outside dimensions
- lifting points location.
For safe lifting to prevent material damages and/or personal injuries, it is recommended to use ropes, or
belts properly positioned on the pump and/or lifting eyebolts and make correct movements.
Lifting eyebolts fitted on single components of the assembly (pump or motor) should not be used to lift
the total assembly.
The fig. 1 and 2 show several additional examples of lifting.
Avoid lifts whereby the ropes or straps, form a triangle with the top angle over 90°(see fig. 3).
The methods of lifting as shown in fig. 4 are to be
absolutely avoided
. Lifting the pump from the shaft end must be
avoided. Should the pump relocation be required, after it has been in use,the pump and its respective auxiliary piping and
interior must be emptied and cleared of service liquid. All its openings which lead to the inside of the pump have to be
well closed and sealed; for removal from the installation see chapter 15.
Summary of Contents for TRSK 2002/1
Page 1: ... NA4 IS VUOC IN00 Rev 3 8_11 2020 OPERATING MANUAL LIQUID RING VACUUM PUMPS TRVK TRSK ...
Page 10: ...Operating manual liquid ring vacuum pumps TRVK TRSK 10 90 OK NO Fig 2 Fig 4 Fig 1 Fig 3 ...
Page 28: ...Operating manual liquid ring vacuum pumps TRVK TRSK 28 blank page ...
Page 29: ...Operating manual liquid ring vacuum pumps TRVK TRSK 29 blank page ...