background image

 

Termination 

 

Unused coaxial connections should be terminated with 75 Ohm  

 

terminating resistors. For DC-supplied connections, DC voltage  

 

decoupling must be used or use 75 Ohm terminating resistors with 

integrated DC decoupling. 

 
 

Attention

 

 

This module contains ESD components!  

 

(ESD = Electrostatic Sensitive Device).  

 

An electrostatic discharge is an electrical current pulse, which can 

flow through an electrically insulated material, when triggered by a large voltage 
difference. To ensure the reliability of ESD components, it is necessary to 
consider their most important handling rules: 
» Pay attention permanently to potential equalisation (equipotential bonding)! 
» Use wrist straps and approved footwear for personnel grounding! 
» Avoid electrostatically chargeable materials such as normal PE, PVC,   
   polystyrene! 
» Avoid electrostatic fields >100 V/cm! 
» Use only labeled and defined packing and transportation materials! 

Damage caused by faulty connections and/or improper handling are 
excluded from any liability. 
 
 

Recycling 

 

All of our packaging materials (packaging, identification sheets, plastic 

 

foil and bags) are fully recyclable. The devices are to be disposed of  

 

properly according to the current disposal regulations of your 

district/country/state as electronic scrap. 

    

WEEE-Reg.-Nr. DE 51035844

 

 

 

Guarantee conditions 

 

The general terms and conditions of Polytron-Vertrieb GmbH apply. 

 

The general terms and conditions can be found on our website at:  

 

https://polytron.de/index.php/en/company/general-terms-and-

 

conditions

.

 

 

 

 

Select installation site 

 

Plan the installation location so that children cannot play with the device 

 

and its connections. The device should only be installed on a solid, flat  

 

and most of all fire-resistant surface. Observe the operation position of 

the devices specified in the operating instructions. Avoid strong magnetic fields in 
the surroundings. Too strong a heat effect or accumulation of heat will have an 
adverse effect on the durability. Don't mount directly over or near heating 
systems, open fire sources or the like, where the device is exposed to heat 
radiation or oil vapours. Mount fan-cooled and passively cooled devices so that 
the air can be sucked in unhindered through the lower ventilation slots and heat 
can escape through the upper ventilations slots. Ensure free air circulation, 
ventilation slots must not be covered. Do not place any objects on the devices. 
Installation in recesses, alcoves etc and covering the installation site, e.g. through 
curtains is not allowed. To avoid heat build-up, the correct installation position 
must be observed and all-round, free ventilation must be ensured in accordance 
with the information in the operating instructions! When installing the cabinet, 
sufficient air convection must be possible to ensure that the maximum permissible 
ambient temperature of the device is maintained. 

 

 

Moisture 

 

The devices have no protection against water and may therefore only 

 

be operated and connected in dry rooms. Dripping/splashing water and  

 

high humidity damage the device. If there is condensation, wait until the 

device is completely dry. Select the operating environment according to the 
specified IP protection class.

 

 

 

 

Heat 

 

Housing parts near cooling fins and cooling fins themselves can get  

 

very hot. Therefore, you should not touch these parts. 

 
 

Mounting and service works 

 

The device may only be installed and operated by qualified persons (in  

 

accordance with EN 62368-1) or by persons who have been instructed  

 

by experts in accordance with the rules of technology. Maintenance  

work may only be carried out by qualified service personnel. Before starting the 
service work, switch off the operating voltage and secure it against being switched 
on again. In the event of service or danger, the mains plug serves as a disconnect 
device from the mains voltage and must therefore be accessible and usable at all 
times. In order to guarantee interference immunity, all device covers must be 
screwed tight again after opening. 
Fuses are only to be changed by authorised specialists. Only fuses of the same 
type may be used. 

 
 

Repairs 

 

Repairs may only be carried out by the manufacturer. Improper repairs  

 

can pose significant risks to the user. In the event of malfunctions, the  

 

device must be disconnected from the mains and authorised specialist 

personnel must be consulted. If necessary, the device must be sent to the 
manufacturer. 
 

 

Thunderstorm 

 

According to EN 60728 part 1 safety requirements, due to increased  

 

risk of lightning, maintenance and / or installation work should not be  

 

carried out during thunderstorms on the device or the system. 

High overvoltages (lightning strikes, overvoltages in the power grid) can damage 
insulation that serves to protect against mains voltage. 
 

 

Ambient temperature 

 

The permissible ambient temperatures specified in the technical data  

 

must be observed for operation and storage, even if the climatic  

 

conditions change due to external influences (solar radiation etc.). 

Overheating the device can damage the insulation that serves to isolate the 
mains voltage. 
 

 

 
 

Mounting and safety instructions 

 

Please observe the following safety instructions in order to 
prevent any risks for persons and/or damage to the device, 
as well as to contribute to environmental protection. 
 

Important instructions 

Please read the operating instructions for the device(s) carefully 
before putting into operation! The instructions contain important 
information on installation, environmental conditions, service and 
maintenance. Save the operating instructions for later use. All 
operating instructions can be found on our website at: 

https://polytron.de/index.php/en/services/operating-manuals

  

 

Approved use 

 

Use the device only at the permissible operating locations, under 

 

the permissible environmental conditions and for the purpose  

 

described in the operating instructions.  

If there is no information about the intended use (e.g. operating location, 
environmental conditions) or if the operating instructions do not contain 
any relevant information, you must contact the manufacturer of this device 
to ensure that the device can be installed. If you do not receive any 
information from the manufacturer, the device must not be put into 
operation. 
 

 

Transport 

 

Please check the packaging and the device for damages in  

 

shipment immediately upon receipt. Do not put a damaged 

 

device into operation.  

Transporting the device by the power cord is not permitted as this can 
damage the power cord or the strain relief. Insulation that serves to 
protect against mains voltages can be damaged by excessive loads (e.g. 
fall, shock, vibration).

   

 
 

Attention 

 

The rated voltage on the device must correspond with the mains 

 

voltage to be used. When operating devices with protection  

 

class I, connection to power sockets with a protective conductor  

connection is mandatory. The instructions for operating the device must be  
observed. 
 

 

Grounding and potential equalisation 

 

Please establish grounding and perform potential equalisation  

 

before initial startup. 

 

According to the currently valid version of EN 60728-11, coaxial  

receiving and distribution systems must meet the safety requirements with 
regard to earthing, equipotential bonding etc, even if the device is 
removed. Otherwise, damage to the product, fire, or other dangers can 
occur. In addition, the earth connection on the device can be used. Other 
devices within touching distance are to be integrated in the equipotential 
bonding. Operation without a protective conductor connection, device 
grounding or equipotential bonding is not permitted. If damaged, the 
device must be taken out of operation. 
The electrical system for powering the device, e.g. house installations 
must contain protective devices against excessive currents, earth faults 
and short circuits. 
Follow all applicable national safety regulations and standards. 

 
 

Connection cables 

 

Always install the connection cables with a loop so that  

 

condensed and/or splashing water cannot run into the device. 

 

 

 

§ 

Reviews: