Mounting and service work 

The device may only be installed and operated by qualified persons (in accordance with EN 62368-1) or by persons who have 
been instructed by experts in accordance with the rules of technology. Maintenance work may only be carried out by qualified 
service personnel. Before starting the service work, switch off the operating voltage and secure it against being switched on 
again. In the event of service or danger, the mains plug serves as a disconnect device from the mains voltage and must 
therefore be accessible and usable at all times. In order to guarantee interference immunity, all device covers must be 
screwed tight again after opening. 
Fuses are only to be changed by authorised specialists. Only fuses of the same type may be used. 

 

Repairs 

Repairs may only be carried out by the manufacturer. Improper repairs can pose significant risks to the user. In the event of 
malfunctions, the device must be disconnected from the mains and authorised specialist personnel must be consulted. If 
necessary, the device must be sent to the manufacturer. 

 

Thunderstorm 

According to EN 60728 part 1 safety requirements, due to increased risk of lightning, maintenance and / or installation work 
should not be carried out during thunderstorms on the device or the system. 
High overvoltages (lightning strikes, overvoltages in the power grid) can damage insulation that serves to protect against 
mains voltage. 

 

Ambient temperature 

The permissible ambient temperatures specified in the technical data must be observed for operation and storage, even if the 
climatic conditions change due to external influences (solar radiation etc.). Overheating the device can damage the insulation 
that serves to isolate the mains voltage. 

 

Termination 

Unused coaxial connections should be terminated with 75 Ohm terminating resistors. For DC-supplied connections, DC 
voltage decoupling must be used or use 75 Ohm terminating resistors with integrated DC decoupling. 

 

Attention

 

This module contains ESD components! (ESD = Electrostatic Sensitive Device).  
An electrostatic discharge is an electrical current pulse, which can flow through an electrically insulated material, when 
triggered by a large voltage difference. To ensure the reliability of ESD components, it is necessary to consider their most 
important handling rules: 
» Pay attention permanently to potential equalisation (equipotential bonding)! 
» Use wrist straps and approved footwear for personnel grounding! 
» Avoid electrostatically chargeable materials such as normal PE, PVC, polystyrene! 
» Avoid electrostatic fields >100 V/cm! 
» Use only labeled and defined packing and transportation materials! 

Damage caused by faulty connections and/or improper handling are excluded from any liability. 

 

Recycling 

All of our packaging materials (packaging, identification sheets, plastic foil and bags) are fully recyclable. The devices are to 
be disposed of properly according to the current disposal regulations of your district/country/state as electronic scrap. 

     

                

WEEE-Reg.-Nr. DE 51035844 

 
Guarantee conditions 

The general terms and conditions of Polytron-Vertrieb GmbH apply. The general terms and conditions can be found on our 
website at

https://polytron.de/index.php/en/company/general-terms-and-conditions

 

 

 

Hereby, Polytron-Vertrieb GmbH declares that the devices of  PSG xxx series complies with the Directive 
2014/53/EU. The CE declaration is available at: 

https://polytron.de/index.php/en/services/declarations

.

  

 

      GENERAL INFORMATION ON THE OPERATING INSTRUCTIONS 

  All parameter data are examples only.  

  User adjustable parameters are freely selectable. 

  Menu views can vary slightly depending on the software version; the operability does not change as a result. 

  The images in this manual are for illustrative purposes only. 

 

 

 

 

§ 

Summary of Contents for 9267998

Page 1: ...1 PSG Serie Einzel Kaskaden Multischalter Linienverst rker Stand alone cascadable multiswitches line amplifier Bedienungsanleitung Operating manual 0902411 V2...

Page 2: ...____________________ 8 5 3 Technische Daten PSG 9 Serie _______________________________________________ 9 6 Multischalterserie PSG 13xx C PSG 1313 AMP 10 6 1 Lieferumfang PSG 13 Serie 10 6 2 Funktions...

Page 3: ...zlich kann der Erdungsanschluss am Ger t genutzt werden Ger te im Handbereich sind untereinander in den Potentialausgleich einzubinden Ein Betrieb ohne Schutzleiteranschluss Ger teerdung oder Potentia...

Page 4: ...sorgten Anschl ssen erst f r eine DC Spannungsentkopplung sorgen bzw 75 Ohm Abschlusswiderst nde verwenden mit integrierter DC Entkopplung Achtung Diese Baugruppe enth lt ESD Bauteile ESD Elektrostati...

Page 5: ...FAW 75DC abgeschlossen werden Die Teilnehmer k nnen alle auf den Transpondern befindlichen Programme mit einem handels blichen DVB S S2 Receiver oder TV Ger t mit integriertem DVB S S2 Tuner empfange...

Page 6: ...verst rker PSG 505 AMP 4 1 Lieferumfang PSG 5 Serie PSG 5xx Q Serie PSG 5xx C Serie PSG 505 AMP 1 x PSG 5xx Q mit Netzteil 1 x PSG 5xx C 1 x PSG 505 AMP mit Netzteil 1 x Kurzanleitung 1 x Kurzanleitun...

Page 7: ...264 V 47 63 Hz 27 W 90 264 V 47 63 Hz 40 W PSG 5xx C PSG 505 AMP Typ PSG 508 C PSG 512 Q PSG 512 C PSG 516 C PSG 505 AMP Artikel Nr 9268000 9268003 9268005 9267998 Eing nge 4 SAT 1 TERR Frequenzberei...

Page 8: ...erie PSG 9xx Q Serie PSG 9xx C Serie PSG 909 AMP 1 x PSG 9xx Q mit Netzteil 1 x PSG 9xx C 1 x PSG 909 AMP mit Netzteil 1 x Kurzanleitung 1 x Kurzanleitung 1 x Kurzanleitung 5 2 Funktionselemente PSG 9...

Page 9: ...0 264 V 47 63 Hz 27 W 90 264 V 47 63 Hz 40 W PSG 9xx C PSG 909 AMP Typ PSG 908 C PSG 912 C PSG 916 C PSG 924 C PSG 909 AMP Artikel Nr 9268010 9268030 9268040 9268050 9268060 Eing nge 8 SAT 1 TERR Freq...

Page 10: ...itung 6 2 Funktionselemente PSG 13 Serie PSG 13xx C Serie PSG 1313 AMP 1 Netzteilanschluss DC IN 13 Erdungsklemme 2 SAT ZF Ein nge 14 SAT ZF Eing nge 3 SAT ZF Ein nge 15 SAT ZF Eing nge 4 Terr Eingang...

Page 11: ...dB V Allgemein Schaltkriterien 13 18 V 0 22 kHz DiSEqC 2 0 Stromaufnahme je Receiver 50 mA max Schaltspannung 15 V 1 V LNB Stromversorgung 2000 mA max Betriebsparameter Ma e BxHxT in mm 370x128x54 37...

Page 12: ...Serie PSG 1717 AMP 1 Netzteilanschluss DC IN 15 Erdungsklemme 2 SAT ZF Ein nge 16 SAT ZF Eing nge 3 SAT ZF Ein nge 17 SAT ZF Eing nge 4 Terr Eingang 18 Terr Eingang 5 SAT ZF Ein nge 19 SAT ZF Eing nge...

Page 13: ...n 13 18 V 0 22 kHz DiSEqC 2 0 Stromaufnahme je Receiver 50 mA max Schaltspannung 15 V 1 V LNB Stromversorgung 2000 mA max Betriebsparameter Ma e BxHxT in mm 356x125x53 356x204x53 356x325x53 356x325x53...

Page 14: ...__________________ 20 5 3 Technical data PSG 9 series ________________________________________________ 21 6 Multiswitch series PSG 13xx C PSG 1313 AMP 22 6 1 Delivery content PSG 13 series 22 6 2 Func...

Page 15: ...onnection on the device can be used Other devices within touching distance are to be integrated in the equipotential bonding Operation without a protective conductor connection device grounding or equ...

Page 16: ...ns should be terminated with 75 Ohm terminating resistors For DC supplied connections DC voltage decoupling must be used or use 75 Ohm terminating resistors with integrated DC decoupling Attention Thi...

Page 17: ...terminated with a DC blocked terminal resistor FAW 75DC The subscribers can receive all programs on the transponders with a standard DVB S S2 Receiver or TV set with integrated DVB S S2 tuner It is no...

Page 18: ...05 AMP 4 1 Delivery content PSG 5 series PSG 5xx Q series PSG 5xx C series PSG 505 AMP 1 x PSG 5xx Q with power supply 1 x PSG 5xx C 1 x PSG 505 AMP with power 1 x Quick guide 1 x Quick guide supply 1...

Page 19: ...Power supply 90 264 V 47 63 Hz 27 W 90 264 V 47 63 Hz 40 W PSG 5xx C PSG 505 AMP Type PSG 508 C PSG 512 Q PSG 512 C PSG 516 C PSG 505 AMP Article no 9268000 9268003 9268005 9267998 Inputs 4 SAT 1 TER...

Page 20: ...Q series PSG 9xx C series PSG 909 AMP 1 x PSG 9xx Q with power supply 1 x PSG 9xx C 1 x PSG 909 AMP with power 1 x Quick guide 1 x Quick guide supply 1 x Quick guide 5 2 Function elements PSG 9 serie...

Page 21: ...0 264 V 47 63 Hz 27 W 90 264 V 47 63 Hz 40 W PSG 9xx C PSG 909 AMP Type PSG 908 C PSG 912 C PSG 916 C PSG 924 C PSG 909 AMP Article no 9268010 9268030 9268040 9268050 9268060 Inputs 8 SAT 1 TERR Frequ...

Page 22: ...uide 6 2 Function elements PSG 13 series PSG 13xx C series PSG 1313 AMP 1 Power supply connector DC IN 13 Grounding clamp 2 SAT IF inputs 14 SAT IF inputs 3 SAT IF inputs 15 SAT IF inputs 4 Terr input...

Page 23: ...Common Switching commands 13 18 V 0 22 kHz DiSEqC 2 0 Power consumption per receiver 50 mA max Switching voltage 15 V 1 V LNB supply 2000 mA max Operating parameter Dimensions WxHxD in mm 370x128x54...

Page 24: ...series PSG 1717 AMP 1 Power supply connector DC IN 15 Grounding clamp 2 SAT IF inputs 16 SAT IF inputs 3 SAT IF inputs 17 SAT IF inputs 4 Terr input 18 Terr input 5 SAT IF inputs 19 SAT IF inputs 6 S...

Page 25: ...18 V 0 22 kHz DiSEqC 2 0 Power consumption per receiver 50 mA max Switching voltage 15 V 1 V LNB supply 2000 mA max Operating parameter Dimensions WxHxD in mm 356x125x53 356x204x53 356x325x53 356x325x...

Page 26: ...e 40 Ausg nge Multi switch system for receiving of 4 satellites and terr signals 17 inputs 40 outputs MBA 35118 N Multiswitch 17 IN 8 subscriber OUT Multiswitch 17 IN 8 subscriber OUT Amplifier 17 IN...

Page 27: ...27 Multischalteranlage zum Empfang von 1 Satellit und terr Signalen 5 Eing nge 8 Ausg nge Multi switch system for receiving of 1 satellite and terr signals 5 inputs 8 outputs MBA 35118 N...

Page 28: ...hme H Q Order department 49 0 70 81 1702 0 Technische Hotline Technical hotline 49 0 70 81 1702 0 Telefax 49 0 70 81 1702 50 Internet http www polytron de Email info polytron de Technische nderungen v...

Reviews: