Offset Calibration
5IJTBEWBODFEGVODUJPOBMMPXTZPVUPBEKVTUZPVS$JSDVMBUPSTUFNQFSBUVSF
display to match the temperature reading obtained with another device.
The factory default is 0.0°C.
1. Disconnect the power cord from the electrical outlet.
2. Plug the power cord back into the electrical outlet while pressing
and holding the button.
3. Press the button.
4. Press the
button until OFFSET CALIBRATE appears on the
display.
5. Press
or
to enter the desired value.
6. Press
or wait for the LCD to return to the main operational
display.
The Offset Calibration function will remain enabled until the electrical
power is turned OFF by pressing the
button.
14
www.sousvideprofessional.com
IMPORTANT:
Before changing the Offset Calibration value,
take into consideration that the RTD sensor used in the
Sous Vide Professional is much more accurate than most
kitchen thermometers.
!
NOTE:
The Offset Calibration value is always shown in °C,
even when °F has been selected as the temperature unit.
Your Circulator will automatically convert the °C offset
calibration value to the correct °F display offset value.
!