The guarantee excludes ancillary fittings 
such as contents measuring gauges or 
mechanical pumps. 

Provided that the following criteria are ad-
hered to (applicable to all models):

• 

The enclosed guarantee card is returned 
to Polymaster with evidence of the 
purchase date.

• 

The tank is installed and commissioned 
in accordance with the instructions out-
lined in the Installation and User Manual.

• 

The tank is installed and commissioned 
by a suitably qualified engineer.

• 

The tank has not been subject to misuse, 
careless handling, faulty installation, or 
any repairs have not been attempted 
or carried out other than by authorized, 
qualified service staff.

• 

The tank has been purchased by the 
end user and is not for hire purposes.

• 

The tank is installed above ground.

• 

 The tank is inspected every 6 months or 
every 50,000 litres dispensed, depend-
ing on which occurs first, by a suitably 
qualified service engineer. Immediately 
upon discovery of any defect in the tank 
steps are taken to mitigate loss by con-
tacting the Adblue supplier and if neces-
sary arrange for tank to be drained.

• 

Immediately upon discovery of any 
defect you contact the Guarantor and 
allow a representative to inspect the 
tank and its surroundings and where 
necessary carry our any repairs (before 
any attempts are made to move the 
tank).

• 

Standard and ancillary fittings, repairs 
and  maintenance are to be carried out 
by your nominated agent

1. FIllInG BlueMASTer

®

 TAnK

During the first fill of the tank the level

indicator may show less volume than that 

filled. The level indicator minimum read point 

is placed at the base of the tank. The safe fill 

level must NOT be exceeded.

NOTE: As level gauges can take some time to 

calibrate, the liquid level must be physically 

checked during initial filling.

A.  

Filling should be performed only under 

constant supervision of an authorized person. 

B.

 This tank can only be filled by a tanker 

equipped with a female dry-break coupling.

C. 

Ensure dispensing nozzle is in the holster.

D. 

Fit delivery hose to dry-break coupling. Do 

not fill the internal tank by other means.

e. 

Stop filling when desired amount has been

dispensed into tank or when overfill alarm

is activated.

F. 

Disconnect delivery hose from coupling.

2. DISPenSInG FrOM BlueMASTer

®

  STATIOnS.

A. 

If the unit is a terminal station, please read 

the MC Box manual entirely before use, and 

ensure any users are fully instructed.

B. 

Lift dispensing nozzle from holster.

Ensure the nozzle is clean.

C. 

Turn the pump on and start pumping

immediately.

D. 

Dispense contents into appropriate tank

e. 

When vehicle is full, turn off pump

immediately, ensure the dispensing nozzle

is clean before placing back in holster.

Summary of Contents for AdBlue Bluemaster Series

Page 1: ... Polyethylene Tanks Depot Express Terminal Customised Fit Outs industrial polymaster com au 1300 062 064 Thank you for purchasing a Bluemaster Station This installation guide effective from 1st March 2016 Australian Owned and Made industrial Installation Operation Guide ...

Page 2: ...au Contents Company Profile Environmental Management Polymaster s manufacturing methods embrace environmental considerations as a central philosophy We implement recycled heat technology minimizing on the LPG required to manufacture each product reducing operating costs and most importantly our C02 emissions Excess materials are fully recycled and water re use programs help to lessen our impact on ...

Page 3: ... N B For customised BMS s the following material may not apply For all customised bluemaster stations polymaster takes no responsibility for operation rec ommendations or maintenance and safety guidance Read operation manual in detail before use comply with all instructions herein Operation manual should be kept with the equipment at all times A Installation and use of this product should only be ...

Page 4: ...mended for installation If this is not possible the station should be installed directly on a level secure and non com bustible base Determine if station needs to be secured in place in exposed conditions Do not drill holes in the tank Bluemaster tanks are supplied with an electronic contents gauge and alarms as standard Prior to installing inspect for damage if damaged do not install The guarante...

Page 5: ...d where necessary carry our any repairs before any attempts are made to move the tank Standard and ancillary fittings repairs and maintenance are to be carried out by your nominated agent 1 Filling bluemaster tank During the first fill of the tank the level indicator may show less volume than that filled The level indicator minimum read point is placed at the base of the tank The safe fill level m...

Page 6: ...ial is entering the Bluemaster Station at all times L If the station has not been used for an extended period run contents through the dispenser for at least 10 seconds and dispose of appropriately 6 l industrial polymaster com au This guarantee is not valid for the following defects Mechanical damaged caused by the user dealer or improper maintenance Faults damage or premature wear caused by impr...

Page 7: ...zle 7 50mm Dry Break Coupling 8 Retractable Hose Reel 9 Weather proof Dispensing Cabinet 10 Lockable Door 11 Inner Tank 12 Bund Enclosure PICTORIAL VIEW Terminal MODEL SHOWN Please note Equipment shown in diagram is not standard on all tanks Positioning of equip ment may vary depending on model of your Bluemaster station For further information please refer to ad ditional manuals 1 2 4 5 6 7 8 9 1...

Page 8: ...Hill VIC 3585 PRODUCT CODE ___________________________________ COLOUR _________________________________________ SERIAL NUMBER ___________________________________ FULL NAME _______________________________________ ADDRESS LOCATION OF TANK ________________________ DAYTIME TELEPHONE NO _____________________________ EMAIL ADDRESS____________________________________ DATE OF PURCHASE ____________________...

Reviews: