2
2
IMPORTANT SAFETY INSTRUCTIONS
When installing and using this electrical equipment, basic safety precautions should always be followed, including
the following:
1.
READ AND FOLLOW ALL INSTRUCTIONS
2.
WARNING
- To reduce the risk of injury, do not permit children to use this product unless they are closely
supervised at all times by an adult who is capable of assisting a child in distress.
3.
WARNING
- Risk of electrical shock. Connect only to a grounding type receptacle. This product is provided
with a ground-fault circuit-interrupter. If replacement of the plug or cord is needed, use only identical replace-
ment parts.
4.
WARNING
- To reduce the risk of electrical shock, replace damaged cord (with pump body) immediately.
NEVER bury cord. Locate cord to eliminate abuse or contact from lawn mowers, hedge trimmers, and other
equipment. NEVER use an extension cord to connect unit to electric supply; provide a properly located outlet.
5.
CAUTION
- The power filter is for use with storable pools only. DO NOT use with permanently installed
pools. A storable pool is constructed so that it may be readily disassembled for storage and reassembled to its
original integrity. A permanently installed pool is constructed in or on the ground or in a building so that it can-
not be readily disassembled for storage.
6. The unit is provided with a ground-fault circuit-interrupter (GFCI). To test the GFCI, push the test button. The
GFCI should interrupt power. Push the reset button. Power should be restored. If the GFCI fails to operate in this
manner, the GFCI is defective. If the GFCI interrupts power to the pump without the test button being pushed, a
ground current is flowing, indicating the possibility of an electric shock. Do not use this pump. Disconnect the
pump and have the problem corrected by a qualified service representative before using.
7.
SAVE THESE INSTRUCTIONS.
PRELIMINARY STEPS
1.
READ ALL INSTRUCTIONS CAREFULLY
and get a thorough understanding of what is required to assemble
your Type RS Power Filter.
2. Before you begin to assemble the RS Filter, identify, count, and check all parts needed for assembly. Refer to the “PARTS
LIST”, Page #10, under the quantity needed column for your size pool.
3. It is recommended that you have some PETROLEUM JELLY on hand for lubricating the gaskets and o-rings.
POWER FILTER
IMPORTANT NOTES:
1. Installer shall follow written instructions provided for operation of the circulation systems.
2. All electrical components shall be installed in accordance with Article 680 of the National Electrical Code (NEC) “Swim-
ming Pools, Fountains and Similar Installations” or its latest approved edition.
3. The Filter Cartridge (9) 3-3/4” will hold as many as 2 of the 1” diameter chlorine tablets and the 8” will hold as many
as 6 of the 1” diameter chlorine tablets. Check your chlorine levels to determine the proper number of chlorine tablets to
add. The filter cartridge will automatically dispense chlorine into the pool as the pump runs.
You must have the type of
Filter Cartridge (9) with a central core mesh divider (See page 3) to use the chlorine dispenser. DO NOT use this to
dispense powdered chlorine, shock treatment or any other type of chemicals as damage to the pump, filter cartridge,
and pool will occur.
4. The RS Type pump/filter systems are manufactured by Dongguan Polyfilm Plastic Products Co. Ltd. and UL Listed (file
#E307476) - double insulated and grounded - 115 V.A.C. - 60 Hz. (
ALL
Units must have a minimum of 105 V.A.C. to start
and run properly.)
RS600 Filter System with F600C Pump
46 watts
0.8 amps
580 G.P.H.
RS600 Filter System with F700C Pump
57 watts
1.1 amps
780 G.P.H.
RS1000 Filter System with F700C Pump
57 watts
1.1 amps
780 G.P.H.
RS1000 Filter System with F1000C Pump
80 watts
2.2 amps
1075 G.P.H.
RS1000 Filter System with F1500C Pump
120 watts
2.0 amps
1500 G.P.H.
RS2000 Filter System with F2000C Pump
210 watts
2.2 amps
2000 G.P.H.