IMPORTANT SAFETY INSTRUCTIONS

When installing and using this electrical equipment, basic safety precautions should always be followed, including 

the following:

1.  

READ AND FOLLOW ALL INSTRUCTIONS

2.  

WARNING

 - To reduce the risk of injury, do not permit children to use this product unless they are closely 

supervised at all times by an adult who is capable of assisting a child in distress.

3.  

WARNING

 - Risk of electrical shock.  Connect only to a grounding type receptacle. This product is provided 

with a ground-fault circuit-interrupter. If replacement of the plug or cord is needed, use only identical replace-

ment parts.

4.  

WARNING

 - To reduce the risk of electrical shock, replace damaged cord (with pump body) immediately.  

  NEVER bury cord.  Locate cord to eliminate abuse or contact from lawn mowers, hedge trimmers, and other 

equipment.  NEVER use an extension cord to connect unit to electric supply; provide a properly located outlet.

5.  

CAUTION

 - The power filter is for use with storable pools only.  DO NOT use with permanently installed 

pools.  A storable pool is constructed so that it may be readily disassembled for storage and reassembled to its 

original integrity.  A permanently installed pool is constructed in or on the ground or in a building so that it can-

not be readily disassembled for storage.

6.   The unit is provided with a ground-fault circuit-interrupter (GFCI). To test the GFCI, push the test button. The 

GFCI should interrupt power. Push the reset button. Power should be restored. If the GFCI fails to operate in this 

manner, the GFCI is defective. If the GFCI interrupts power to the pump without the test button being pushed, a 

ground current is flowing, indicating the possibility of an electric shock. Do not use this pump. Disconnect the 

pump and have the problem corrected by a qualified service representative before using.

7.  

SAVE THESE INSTRUCTIONS.

PRELIMINARY STEPS

1. 

READ ALL INSTRUCTIONS CAREFULLY

 

and get a thorough understanding of what is required to assemble 

your Type RS Power Filter.

2.   Before you begin to assemble the RS Filter, identify, count, and check all parts needed for assembly. Refer to the “PARTS 

LIST”, Page #10, under the quantity needed column for your size pool.

3.   It is recommended that you have some PETROLEUM JELLY on hand for lubricating the gaskets and o-rings.

 

POWER FILTER

IMPORTANT NOTES:

1.  Installer shall follow written instructions provided for operation of the circulation systems.
2.  All electrical components shall be installed in accordance with Article 680 of the National Electrical Code (NEC) “Swim-

ming Pools, Fountains and Similar Installations” or its latest approved edition.

3.  The Filter Cartridge (9) 3-3/4” will hold as many as 2 of the 1” diameter chlorine tablets and the 8” will hold as many 

as 6 of the 1” diameter chlorine tablets. Check your chlorine levels to determine the proper number of chlorine tablets to 

add. The filter cartridge will automatically dispense chlorine into the pool as the pump runs. 

You must have the type of 

Filter Cartridge (9) with a central core mesh divider (See page 3) to use the chlorine dispenser. DO NOT use this to 

dispense powdered chlorine, shock treatment or any other type of chemicals as damage to the pump, filter cartridge, 

and pool will occur.

4.   The RS Type pump/filter systems are manufactured by Dongguan Polyfilm Plastic Products Co. Ltd. and UL Listed (file 

#E307476) - double insulated and grounded - 115 V.A.C. - 60 Hz. (

ALL 

Units must have a minimum of 105 V.A.C. to start 

and run properly.) 

RS600 Filter System with F600C Pump

46 watts

0.8 amps

580 G.P.H.

RS600 Filter System with F700C Pump

57 watts

1.1 amps

780 G.P.H.

RS1000 Filter System with F700C Pump

57 watts

1.1 amps

780 G.P.H.

RS1000 Filter System with F1000C Pump

80 watts

2.2 amps

1075 G.P.H.

RS1000 Filter System with F1500C Pump

120 watts

2.0 amps

1500 G.P.H.

RS2000 Filter System with F2000C Pump

210 watts

2.2 amps

2000 G.P.H.

Summary of Contents for RS1000 Filter System with F1000C Pump

Page 1: ... Foam Plastics Corporation at 800 813 0206 2 You should first consult the Trouble Shooting guide for a simple solution page 9 If still unable to correct the situation please contact customer service representative General Foam Plastic s customer service at 800 813 0206 Do not return your pool or parts to the place of purchase A knowledgeable customer service representative will assist you in resolv...

Page 2: ... 7 SAVE THESE INSTRUCTIONS PRELIMINARY STEPS 1 READ ALL INSTRUCTIONS CAREFULLY and get a thorough understanding of what is required to assemble your Type RS Power Filter 2 Before you begin to assemble the RS Filter identify count and check all parts needed for assembly Refer to the PARTS LIST Page 10 under the quantity needed column for your size pool 3 It is recommended that you have some PETROLE...

Page 3: ... 17 THRUST WASHER WHITE 18 NUT 19 ELBOW 90 20 DIVERTER FITTING 21 LOCKING RING 22 GASKET 23 FACE PLATE 24 WALL POCKET POOL 25 POOL WALL 26 HEX HEAD SCREWS 27 WEIR FOAM 28 WEIR 29 VACUUM ADAPTER 30 SERVICE PLUGS 3 16 21 17 18 19 30 14 12 1 6 11 9 25 30 7 24 8 22 14 12 26 23 27 28 29 22 12 Ea IMPORTANT Your pump is protected by a thermal overload This device senses the temperature of the pump and if...

Page 4: ...s each Then proceed in tightening them in equal turns each in sequence around the Face Plate until all are equally tight and you have a good even seal Warning Be sure not to over tighten them you just need a water tight seal B Now lubricate the pump O ring 5 liberally with petroleum jelly not provided Hold the Skimmer Canister 8 securely and insert pump assembly 1 6 so that the outlet on the Volut...

Page 5: ... there is no water leakage If any leaks are found see 4 in the Trouble Shooting guide on page 9 G Refer back to your Above Ground Quick Set Swimming Pool Manual making sure you have read and com pleted ALL INSTRUCTIONS PROPERLY before continuing to step 2 page 5 in this manual 2 PUMP MOTOR PROTECTION 3 PUMP OPERATION IMPORTANT FILTER CARTRIDGE MUST BE FIRMLY SEATED OVER THE PUMP INTAKE PORT TO FIL...

Page 6: ... more easily removed from the filter pleats when the cartridge is dry Therefore after hosing the cartridge allow the filter to dry and CAREFULLY BRUSH but do not scrub the pleated surface areas Cleaning and scrubbing a filter too vigorously will also wear out the cartridge much faster than if it is simply hosed off correctly C Suntan oils body oils and algae can form a coating on the filter pleats whi...

Page 7: ...u need to reinstall it after vacuuming so that your skimmer operates properly 4 Next attach your vacuum to it s handle and place the swivel end of the hose on the vacuum unit and lower vacuum into the pool Place your vacuum hose into the pool it will float somewhat keep the remaining end near the DIVERTER FITTING now turn on the pump and hold the hose up to the DIVERTER FITTING filling the hose this...

Page 8: ...l supplier for analysis before adding ANY chemicals 6 Use the gallons for your pool to calculate the amount of chemicals you will need to correct the pool water based on the gallons of water in your pool Note It is recommended to use a 5 gallon bucket of water to mix and dis solve your chemicals and then applying directly to the pool water Follow manufacturers label directions on all chemicals For...

Page 9: ...be plugged into a 3 wire grounded outlet kicks on and off B GFCI Breaker Tripped B Reset circuit breaker If problem persists have an electrician check circuit C Low Voltage C Check line voltage must be 105 to 125 AC volts D Rotor Jammed D See the Rotor Service diagram in the assembly view of the Filter Pump unit page 3 2 No flow or low flow A Low Water Level A Water level must be within 1 above or b...

Reviews: