background image

WARRANTY

(For the Original Owner Only)

(For Warranty Information, Please Mail to Manufacturer.)

Customer’s Name :   
Address :  
Phone : 

Unit

Serial # :
Model # :
Date Purchased :    
Installer’s Name : 

K-Star Pool/Spa Heater is guaranteed for a period of one year from the date
of its purchase to the original owner against any manufacturing defects.
Exception: factory installed heating elements carry a 90 day limited 
manufacturer warranty from date of heater installation only.

Any warranty claim must be pre-authorized by Consolidated Pool & Spa
Industries Inc. and claim must include: Model number, Serial number and
Date of purchase. Any defective unit shall be returned freight prepaid only.
Consolidated Pool & Spa Industries Inc. will not be responsible for
disconnection-reconnection charges.

The above warranty shall be considered void if:

i. 

The installation instructions are not followed.

ii. 

Unit is powered without any water circulation.

iii.  The power is disconnected and unit is not thoroughly drained at time of 

winterizing.

iv.  The Unit has been mishandled.
v. 

If corrosion of the unit’s internal parts occurs by unit being exposed to a 
salt water system, a system that uses salt to create a sanitizer or improper 
water chemistry (applies to all non-titanium heater models only). Warranty 
Registration must be done within ten days of purchase of the unit, by 
mailing warranty card below to:

361 Rowntree Dairy Road, Unit 4 
Woodbridge, ON L4L 8H1 Canada

Tel: 905.264.6496 Fax: 905.264.6508
Email:[email protected]

INSTRUCTION MANUAL

MODELS:

K-5-D / K-10-D / K-15-D
(Regular elements/digital Thermostat)

K-5-TT-D / K-10-TT-D / K-15-TT-D
(Titanium elements/digital Thermostat)

“K-STAR” DIGITAL

Electric Pool/Spa Heaters 

361 Rowntree Dairy Road, Unit 4 
Woodbridge, ON L4L 8H1 Canada

Tel: 905.264.6496 Fax: 905.264.6508
Email:[email protected]

Summary of Contents for K-5-D

Page 1: ...ed void if i The installation instructions are not followed ii Unit is powered without any water circulation iii The power is disconnected and unit is not thoroughly drained at time of winterizing iv The Unit has been mishandled v If corrosion of the unit s internal parts occurs by unit being exposed to a salt water system a system that uses salt to create a sanitizer or improper water chemistry a...

Page 2: ...tors shall be grounded properly to the unit The installation of the collectors shall be such that all ows through the two current collectors as shown in Figure 01 The length of the leakage current collectors shall be made of a corrosion resistant metal and shall be provided with a copper lug brazed to the collector body Hand tighten only Do not use high force with a pipe wrench 1a READ AND FOLLOW ...

Page 3: ...he heater breaker off Allow the heater to cool and then depress the high limit as shown in Figure 04 1 FIGURE 04 HIGH LIMIT RESET THERMOSTAT LOCATED UNDERNEATH 3 SHOWING BY PASS FIGURE 02 The Heater shall be installed as per Figure 02 The water inlet and outlets are connected to straight pipe connectors of the heater i Do not store chlorine near or in the same room as heater ii Valves must not be ...

Page 4: ...essure Down decreases water pressure LO Low water temperature is detected meaning that the temperature is below the range of the thermostat Heater is still running Follow point 3 instructions to correct this error code HI HAUT LOC High water temperature is detected meaning that the water temperature goes above the range of the thermostat see point 3 for highest temperature setting The Heater will ...

Page 5: ...emperature setting by one degree or Press and hold UP or DOWN button to rapidly increase or decrease the temperature setting 3b Once desired Pool or Spa temperature has been set the heater will start up 3c After 5 seconds without pressing any buttons the unit will automatically display the actual water temperature 2 3 5 A green coloured terminal or a wire connector marked C GP Ground or Grounding ...

Page 6: ...r OFF Selecting temperature SCALE choose F Fahrenheit or C Celsius 1a to access the temperature SCale selection the unit has to be in Set point mode showing either OFF or decimal points 1b Press and hold POOL SPA button for three seconds and release when the display shows SC for Scale The display will show SC for one second Press UP or DOWN button to toggle between Celsius and Fahrenheit mode Choo...

Reviews: