ReadiVoice PSPI Reference
82
Proprietary & Confidential
Return Values
vConfTermTime
SMALLINT 5–480
Auto termination time in minutes. Set to 480 if
not using.
vPartPlayCount
SMALLINT 0,
1
Conference entry with participant count.
0: Off; 1: On.
vDialOutPreFix CHAR
(30)
Number to dial before dialing out (numeric
characters only). Set to empty string if not
used.
vDialOutPostFix CHAR
(30)
Number to dial after dialing out (numeric
characters only). Set to empty string if not
used.
vLOEntry SMALLINT
0,
1
Listen Only Entry option (conferences start
with all but subscriber in Listen Only mode).
0: Off; 1: On.
vLOEntryEnable SMALLINT
0,
1
Listen Only Entry option changeable by
subscriber (for future conferences).
0: No; 1: Yes.
vWROption
SMALLINT 0–2
WR option (conference lock type). 0: Normal
lock; 1: Lock w/ WR (Waiting Room available
when conf. is locked); 2: WR on entry (conf.
starts out locked with Waiting Room enabled).
vWROptionEnable SMALLINT 0,
1
WR Enable flag (conference lock type
changeable). 0: No; 1: Yes.
Data Type
Description
INT
Return code (0: OK; otherwise, error code).
Parameter
Data Type
Constraints
Description