PU1000/PU600 INSTALLATION MANUAL

 

  

 

 

                                            

 

10229-15.doc

Polyamp AB, Sweden 

www.polyamp.com 

Page 

3 (10) 

 

 

CONTENTS 

 

1  BEFORE INSTALLATION..............................................................................................................................4

 

2  INSTALLATION ...............................................................................................................................................4

 

3  PARALLEL CONNECTION ...........................................................................................................................5

 

3.1

  

S

ERIES DIODE ON THE OUTPUT

........................................................................................................................5

 

3.2

  

C

URRENT SHARING

.........................................................................................................................................5

 

3.3

 

V

OLTAGE ADJUSTMENT WITH CURRENT SHARING

.....................................................................................6

 

4  MULTIPLE LOADS AT THE OUTPUT ........................................................................................................6

 

4.1

  

S

HORT

-

CIRCUITS

............................................................................................................................................6

 

5  ALARM ..............................................................................................................................................................7

 

5.1

  

O

VER AND UNDER VOLTAGE ALARM

..............................................................................................................7

 

5.2

  

O

VER TEMPERATURE

......................................................................................................................................7

 

6  SENSE.................................................................................................................................................................7

 

6.1

  

E

XTERNAL SENSE

...........................................................................................................................................7

 

6.2

  

I

NTERNAL SENSE

............................................................................................................................................8

 

7  INHIBIT .............................................................................................................................................................8

 

8  OUTPUT OVER VOLTAGE PROTECTION................................................................................................8

 

9  INRUSH CURRENT LIMIT ............................................................................................................................8

 

10  ISOLATION VOLTAGE TEST.....................................................................................................................8

 

10.1

  

DC

 ISOLATION TEST OUTPUT TO CASE

..........................................................................................................8

 

10.2

 

DC

 ISOLATION TEST INPUT TO OUTPUT AND INPUT TO CASE

......................................................................9

 

10.3

 

AC

 ISOLATION TEST INPUT TO OUTPUT AND INPUT TO CASE

......................................................................9

 

11  TROUBLE SHOOTING .................................................................................................................................9

 

11.1

  

T

HERE IS NO OUTPUT VOLTAGE

....................................................................................................................9

 

11.2

 

T

HE INPUT FUSE BLOWS WHEN THE INPUT IS CONNECTED

..........................................................................9

 

11.3

 

T

HE CONVERTER STARTS AND STOPS REPEATEDLY

.................................................................................10

 

11.4

 

T

HE CONVERTER STOPS AFTER SEVERAL HOURS

.....................................................................................10

 

11.5

  

F

AULT REPORT

...........................................................................................................................................10

 

 

 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for PU1000

Page 1: ...PU1000 PU600 INSTALLATION MANUAL 10229 15 doc Polyamp AB Sweden www polyamp com Page 1 10 PU1000 PU600 Installation manual...

Page 2: ...information may have been updated since then Polyamp AB reserves the right to make changes in this manual without notice The exclamation point within an equilateral triangle is intended to alert the u...

Page 3: ...5 2 OVER TEMPERATURE 7 6 SENSE 7 6 1 EXTERNAL SENSE 7 6 2 INTERNAL SENSE 8 7 INHIBIT 8 8 OUTPUT OVER VOLTAGE PROTECTION 8 9 INRUSH CURRENT LIMIT 8 10 ISOLATION VOLTAGE TEST 8 10 1 DC ISOLATION TEST OU...

Page 4: ...l disconnection device which is able to disconnect both polarities shall be incorporated with the input power supply cord The disconnection device must be properly labelled and easy accessible 2 Insta...

Page 5: ...ly or if you require redundant operation If a converter breaks down with an internal short circuit on the output and other converters are connected in parallel on the output the broken unit will short...

Page 6: ...ntil the C MASTER LED is lit or almost lit 4 Multiple loads at the output If you are using several loads we recommend fusing them separately with fast acting fuses on the positive output branch Some c...

Page 7: ...r and connector pin marked NORMAL Figure 3 Alarm contact The relay is isolated 2500Va c from input output and case The relay can switch maximum 30V 5A a c and d c values 5 1 Over and under voltage ala...

Page 8: ...hibit 8 Output over voltage protection All models are equipped with an internal output over voltage protection circuit OVP It consists of an additional voltage regulator operating in parallel with the...

Page 9: ...solation test input to output and input to case above but test with 4000Vd c instead of 2000Vd c The leakage current should not exceed 5 A AC isolation test 1 Disconnect all cables from the converter...

Page 10: ...ay be under sized causing too high voltage drop in the supply cables 2 Your supply does not have enough current capacity so the input voltage to the converter drops below specified limit 11 4 The conv...

Reviews: