background image

ZONEMASTER ZONETOUCH V2 ZONE CONTROL SYSTEM - User Manual

 15

8) Specifications

 

  Electrical Requirements
    Power supply:  

 

24V AC ±10% 

    Line frequency: 

 

50 Hz

  Components Power Consumption
    Touchpad:  

 

0.5 VA 

    Main Control Module: 

  

5 VA

  Environmental Requirements
    Operating temperature:  

 

0°C to 60°C 

    Altitude:  

 

0 to 2000 meters  

    Operating relative humidity:   

10% to 80%  

    Avoid static electricity hazards
    Avoid electromagnetic radiation sources
    Avoid dust contamination
    Avoid highly corrosive environments

  Zone Output
    Output voltage: 

  

24VAC, 50Hz

    Current:  

 

200mA (1 damper motor)

  Transformer
    Input Voltage: 

 

240V AC, 50Hz  

    Output Voltage: 

 

24VAC, 50Hz  

 

    Wattage:  

 

40W

  Supply Air Sensor: 

 

NTC type, 10 kΩ at 25°C

  Battery: 

 

3.6V, 3xAAAM  

       

 

Rechargeable for Main Module

  Fuse: 

 

Dimension 5x20 mm,  

       

 

Fast-Acting 2A, 250V

  

Summary of Contents for ZoneMaser ZoneTouch V2

Page 1: ...ZoneTouch V2 Zone Control System User Manual www polyaire com au 2014 Polyaire Pty Ltd...

Page 2: ...ZONEMASTER ZONETOUCH V2 ZONE CONTROL SYSTEM User Manual II...

Page 3: ...p 7 5 User Settings 8 5 1 Time Date setup 8 5 2 Owner s Name 9 5 3 Turbo Group 9 5 4 Temperature Display 10 5 5 Touch Tone 10 6 Information Sheets 11 7 Troubleshooting Guide 14 8 Specifications 15 TAB...

Page 4: ...nes automatically resume their original on off state once power is restored after power outage 1 A zone is the area where air supply is controlled by one motorized damper 2 A group is a few zones grou...

Page 5: ...ouch tone status and ZoneTouch logo as shown in Figure 1 NOTE The touch screen will go to the sleep mode after 90 seconds of inactivity In sleep mode the screen is blank Touching any area of the scree...

Page 6: ...p will open or close accordingly b The group status can be set to TURBO active when the group is specified as a turbo group refer to 5 3 and the grey turbo indicator will turn blue to indicate the TUR...

Page 7: ...nt event time slots NOTE A group can have up to a maximum of 4 zones Your installer would have already set up your zones and groups 3 2 Adjusting airflow for a group The damper opening percentage for...

Page 8: ...he home screen to enter Programming screen Figure 4 Figure 4 Figure 6 b Touch a day option radio button to select Monday Friday Saturday or Sunday program to modify Touch the time switch radio button...

Page 9: ...uch the program field of a group to show all program options Figure 8 Touching a program option will assign the program to the group Figure 9 Each group can be assigned with one program from program1...

Page 10: ...e Touching button will go back to the home screen from User setting pages Figure 11 Figure 12 5 User Settings Figure 13 Figure 14 5 1 Time Date setup a Touch on the User Settings screen Figure 12 to e...

Page 11: ...l other groups dampers opening positions are reduced by 50 of their open percentage value This will bring a large volume of extra air into the designated area and cool or heat the area quicker Typical...

Page 12: ...screen Below images show the enabled status Figure 17 and disabled status Figure 18 of temperature display 5 5 Touch Tone The touch tone feature allows to either enable or disable the tone when the s...

Page 13: ...ormation Sheets These should be filled out by the installer Total Groups Bypass Damper Installed Supply Air Sensor Installed Yes No Yes No Group Group Name Zones Included Turbo Function 1 2 3 4 5 6 7...

Page 14: ...ROL SYSTEM User Manual 12 Installer Contact Number Date Zone Balance Percentage Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 Zone 7 Zone 8 Zone 9 Zone A Zone B Zone C Zone D Zone E Zone F Zone G Table 4...

Page 15: ...Off time 2 Monday Friday Saturday Sunday Groups PROGRAM 2 On time 1 Off time 1 On time 2 Off time 2 Monday Friday Saturday Sunday Groups PROGRAM 3 On time 1 Off time 1 On time 2 Off time 2 Monday Fri...

Page 16: ...the Group status in the home screen Opening other zones will rectify the error If all zones are turned on but the total opening percentage doesn t meet the required spill percentage then the SPILL war...

Page 17: ...Altitude 0 to 2000 meters Operating relative humidity 10 to 80 Avoid static electricity hazards Avoid electromagnetic radiation sources Avoid dust contamination Avoid highly corrosive environments Zo...

Page 18: ...ZONEMASTER ZONETOUCH V2 ZONE CONTROL SYSTEM User Manual 16...

Page 19: ...ZONEMASTER ZONETOUCH V2 ZONE CONTROL SYSTEM User Manual 17...

Page 20: ...ZMZT2_USER_V1 0 POLYAIRE PTY LTD 11 13 WHITE ROAD GEPPS CROSS SOUTH AUSTRALIA 5094 TEL 08 8349 8466 FAX 08 8349 8446 www polyaire com au...

Reviews: