SANI SYSTEM CHECK
26
ENGLISH
TIPS FOR USE
Before treating delicate or special surfaces
with the SANI SYSTEM POLTI sanitising sy-
stem, consult the manufacturer’s instructions
and carry out a test on a hidden part of the
surface or on a sample of the material.
Allow the sanitised part to dry to make sure
that no changes in colour or deformations
have occurred.
Make sure that the surface to be treated is
clean before sanitising it. In the event of
visible dirt, clean the surface before saniti-
sing it.
Direct the steam downwards for 2 se-
conds in order to bring all the components
of the machine to their correct tempera-
ture, in order to avoid condensation.
Bring the delivery nozzle into a position per-
pendicular to the surface to be sanitised and
keep it at a distance of 10 cm, as provided by
the spacer, avoiding direct contact of the lat-
ter with the surface. Deliver the steam on a
continuous movement, using “brushing” mo-
vements to cover the surface to be sanitised.
Repeated treatments will lead to more efficient
sanitising of the treated surfaces.
SANI SYSTEM POLTI delivers saturated
steam that, added to HPMED, will dry without
leaving residues within 30 seconds to 1 mi-
nute, depending on the environmental condi-
tions.
To sanitise piping, drains, etc., connect the
delivery nozzle to the adaptor (
R
), to obtain a
concentrated output jet of steam. Before star-
ting to use the device, make sure that the ma-
terial to be treated can withstand the high
temperature.
PRESSURE INDICATOR
Precision:
Class 2.5
This device has a handy and accurate indica-
tor (
F
) for displaying the operating pressure
immediately. When the device is on stand-by,
that is to say it is switched on but no steam is
being delivered, the pressure is kept steady
at between 4 and 6 bars.
DISPOSABLE BOTTLE OF
HPMED
• Unscrew the cap of the disposable bottle.
• Screw the bottle (
Q1
) to the fitting (
Q
) as
shown in Figure 3.
• To connect and disconnect the disposable
adapter to SANI SYSTEM delivery device, fit
the coupling on the upper part of the con-
nector (
Q
) into the one placed on the bottom
of the delivery device, pressing them to-
gether until they click into place (fig.4). To di-
sconnect the connector, simply press the le-
ver on it and separate the two components
(fig.5).
As soon as the level of HPMED contained in
the disposable bottle drops below the low level
indicated on the label, replace it with a new
bottle.
Once the disposable bottle has been opened
and fitted onto the delivery nozzle, the sanitis-
ing efficiency of the product is guaranteed for 7
days. If the bottle has been only partly used af-
ter this period of time, it is in any case advis-
able, therefore, to remove it and replace it with
a new one.
Do not refill the disposable bottle.
To carry out correct sanitising, we recommend
reading the instructions for using Sani System
carefully.
CONNECTION OF ACCESSORIES
The following accessories can be connected
to the delivery nozzle:
Adaptor for creating concentrated steam
jet (R)
:This accessory provides a concentra-
ted output jet of steam. To fit this accessory
match up the teeth on the adaptor with the
openings on the tip of the nozzle. Place the
accessories against the nozzle, pushing it as
far as it will go, then turn it in a clockwise di-
rection (Fig. 6).
WARNING!
When using this acces-
sory, the connector of the disposable
bottle (
Q
) must not be connected to
the delivery device.
SANI SYSTEM CHECK
NO MEDICALE - 1T03 ITA - EN 1T10:A5
31/10/2013
10.12
Pagina 26
Summary of Contents for SANI SYSTEM CHECK
Page 1: ...SANI SYSTEM CHECK NO MEDICALE 1T03 ITA EN 1T10 A5 31 10 2013 10 11 Pagina 1 ...
Page 4: ...SANI SYSTEM CHECK NO MEDICALE 1T03 ITA EN 1T10 A5 31 10 2013 10 12 Pagina 4 ...
Page 30: ...NOTES SANI SYSTEM CHECK NO MEDICALE 1T03 ITA EN 1T10 A5 31 10 2013 10 12 Pagina 30 ...
Page 31: ...NOTES SANI SYSTEM CHECK NO MEDICALE 1T03 ITA EN 1T10 A5 31 10 2013 10 12 Pagina 31 ...