Politec S.r.l. | Manual SADRIN – Ver. 3.3
9
5.
CABLES & CABLING
Cablings must be done by two separate cables:
o
One (type screened 0.5 mm ² minimum) supplies barrier and allows the transmission of the alarm
signal and the tamper.
o
One (type screened 0.22 mm ² minimum) is synchronism cable to link TX and RX.
The screen of these cables must be connected to negative of 13.8 VDC in terminal
blocks of each column.
6.
TECHNICAL FEATURES
MODEL
SADRIN 205
SADRIN 410 SADRIN 615 SADRIN 820
Max range outdoor
Black 15m; White 5m
Synchronism
wired
Dual beam optical
Yes with 35mm lenses in AND
Max configuration
2TX+2RX
4TX+4RX
6TX+6RX
8TX+8RX
Beam operating
Parallel
Supply
13,8 Vdc
Consumption (tx+rx)
60mA
90mA
120mA
150mA
Optional heaters
Up to -50°C, 12Vdc
From 560mA to 3920mA tx + rx)
Alarm output
Free contact relay (on RX side)
Tamper output
On both columns
Protection degree
IP54
Dimensions
25mm x 22 mm from 500 to 4000mm
Weight per column
250g
500g
750g
1000g
12Vdc screen alarm cable