Politec S.r.l. | Manual SADRIN – Ver. 3.3
7
Power on barriers and check SYNC LEDs are flashing on both Transmitter
and Receiver mother boards. In case whereby only TX LED is on, check
synchronism connection.
Test function of barrier interrupting a pair of beams at a time, this must report
an ALARM event, signaled by RED LED and relay opening.
After test, complete installation choosing desired operation mode for the
barrier, as shown in table below.
After programming, if desired, is possible to turn off LED ALARM on mother boards by a jumper. Close
barriers hanging plastic IR profile on aluminum and closing the top caps.
FUNCTION
DIP POSITION
DELAY
AND
AND - ON
500ms
FAST - OFF
FAST
AND - OFF
100ms
FAST - ON
NORMAL
AND - OFF
250ms
FAST - OFF
LED ALARM ON
me
LED ALARM OFF