Politec S.r.l. | Manual SADRIN – Ver. 3.3
6
3.
INSTALLATION
Adjust beams height by loosening screws on the boards, and positioning at requested height, make connections
to terminal blocks and seal cable passages to prevent entry of water and insects.
Make sure all boards screws are tightened so that there is a physical contact between boards and aluminum
profile, to obtain an electric screening for prevent interferences.
Select and activate, through dip switches, the number of beams installed in barrier.
Make sure that expansions are properly connected (OUT>IN).
BEAM: move ON DIPSWITCH up to
corresponding number of expansions present
in barriers. The missed activation of
DIPSWITCH exclude relative beam operation.
(Example: 6 expansions added)
AND
:
in ON
activates double-beam detection
(time delay 500 msec)
FAST
: single-beam detection
(with faster time delay 100 msec)
Board fixing screw
LED SYNC
: indicates the operation of the
synchronism
Summary of Contents for SADRIN
Page 1: ...Installation manual...