9.15
TECHNICAL SPECIFICATION IR
OPTICS
Impulsive double lenses 950 nm
DISQUALIFICATION
Automatic with signaling out, open collector negative
MASKING
Detection of blindness by another infrared signal by signaling out, open
collector negative.
OPERATING TEMPERATURE
- 25°C / + 65°C. Available Kit heaters for temperatures down to -50 ° C.
ADJUSTMENT ANGLE
10° vertical
–
180° horizontal
DETECTION OPTIONS
And/Or on Rx / AND 1° + 2°.
BEAMS EXCLUSION
1° / 1° + 2°
REMOTE CONTROLS
AND Random / AND 1° + 2° beam / exclusion 1° o 1° e 2°
10.
DT3 SECTION
10.1
DETECTION AREA
Regolando opportunamente la sensibilità è possibile coprire completamente le zone morte immediatamente
sottostanti e sovrastanti la parabola MW.
IR
IR
MW
3
DT3
DT3