17.4 Advanced configurations - Gapid SR
Enable net cut time:
Through this function it is possible to keep the vibration in memory for a timing expressed in
days.
N.B.:This function greatly increases the
system sensitivity.
Resonance:
To use this function, the TEST function must also be activated.With this function it is possible to
record the spontaneous vibration of the fence on a single sensor.To register it, it is necessary a single
hit to the fence and verify its registration by viewing the status of the single sensor.
In the presence of Resonance, the alarm on a single sensor will be excluded.The "Recorded
Resonance" flag indicates that the sensor has recorded this type of vibration and will be ready to filter
it in the future.