17.5 Advanced configurations - System configuration
Gapid SR on COM1
:Number of sensors set on the first serial port
Gapid SR on COM2
:Number of sensors set on the second serial port
Saving Time Value
:Time interval expressed in seconds to validate the control unit algorithms.The
system retains the number of peak vibrations of each sensor for 30s by default.
Close Gapid SR percentage
:The system generates a Group alarm if the sensors adjacent to the
alarmed sensor have registered a certain number of vibrations.This number is equal to the percentage
of the indicated alarm threshold.E.g.If a sensor generates a pre-alarm after 10 vibrations and the
percentage is 20%.Adjacent sensors must register at least 2 vibrations.
Max BadCom \ Day
:Maximum number of badcoms per day to record an alert
Inputs 2-8
: not enabled in the future.