Table 6 - Troubleshooting quick guide

Symptom

Possible problem

Action

Instrument will not pass 

calibration tests

(Section 7)

One electrode is bad

See section 11.2.

Zinc coupon is passive (more 

positive than (-) 1.000V)

Remove zinc coupon and clean with file or 

sandpaper

Readings more positive than (-) 

1.000V

Inspect the tip wire for any damage.

Electrodes are dry

Allow to soak for 30 minutes and retry

Readings more negative than (-) 

1.100V

Issue the Cal! command through the RS232 

interface.

Both electrodes reading low

Tip wire damaged

Remove probe tail assembly, unplug tip wire, 

remove nose cone, inspect tip wire and repair 

with ScotchKote® as a temporary measure. 

Order replacement nose cone.

Readings are not steady and 

continue to change.

Poor structure contact

Re-stab to ensure contact.

One reading suddenly goes 

less negative

Connector is flooded.

Check connectors.

Lead wire (flying lead) is nicked.

Inspect and repair / replace as necessary.

Displays are blank

Whip is cut or power polarity is 

inverted.

Check cabling and wiring. 

Displays are too dim or 

blurry

Intensity is set too high or low for the 

available camera.

Increase intensity of light shining on meter.  

Adjust the intensity using the command line. 

See Table 5 - RS232 Command List

Garbled data stream output

Ground fault or improper shielding

Ensure RS232 signal ground and power 

ground are tied together subsea. Ensure 

RS232 signal ground is connected topside.

No data stream output

Broken wire in whip

Perform a loop-back test to verify 

communications. Visually inspect whip for 

damage.

Incorrect port

Perform a loop-back test to verify 

communications.

Swapped transmit / receive

Try swapping the transmit and receive wires on 

topside connection.

Voltage on transmission line

Insert a null modem between ROV and 

computer

If problem persists or is not listed, please call our hotline at (713) 983-7117 and ask for Polatrak 

technical support.

14.

  

Spare parts and accessories

14.1

  The Deep C Meter 300 AD is shipped in a waterproof transit case and contains the following 

spares and accessories. Please contact your Deepwater representative to order additional spares if 

required.

14.1.1

 

 

Zinc 

calibration 

block 

     (1) 

14.1.2

 

 

Contact 

tips 

      (3)

14.1.3

 

 

Lens 

retaining 

screws 

     (4)

Summary of Contents for Deep C Meter 300 AD

Page 1: ...B 001 Deep C Meter 300 AD Manual 2015 Deepwater Corrosion Services Inc Specifications subject to change without notice Deep C Meter 300 AD ROV mounted CP probe Operation manual ROV interfaced cathodic protection monitoring system Can output both contact and EFG probe readings Digital output RS232 standard ASCII string No batteries ROV 24V DC powered ...

Page 2: ...Deep C Meter AD calibration 8 7 2 Bucket calibration 9 7 3 Subsea calibrations 9 7 4 Online calibration 9 8 Operation 10 8 1 Mounting on ROV 10 9 Taking CP potential readings 11 10 Data interpretation 11 10 1 Removal from ROV 11 11 Maintenance and repair 12 11 1 Tip replacement 12 11 2 Electrode element replacement 12 12 RS232 functions 13 12 1 Data output 13 12 2 Control data input 13 13 Troubles...

Page 3: ...able 7 List of spare parts 15 1 Overview The Deep C Meter 300 AD is a complete ROV interfaced cathodic protection monitoring system The system comprises five basic parts 1 1 LED readout Triple voltmeters housed in a Delrin pressure housing 1 2 Contact probe Twin element tip contact CP probe Polatrak Model ROV II 1 3 Flying lead Three meter long umbilical that connects the probe to the readout 1 4 ...

Page 4: ...sure housing to change batteries 2 Documentation The following documents are contained in the appendix 2 1 ROV II Operations Manual 354 MN01 ENG 2 2 EFG 1 Operations Manual 358 MN02 ENG 2 3 RUSS Operation Manual 358 MN04 ENG 2 4 Parker Seals Parker O Lube MSDS O ring lubricant 2 5 Dow Corning 4 Electrical Insulating Compound MSDS connector sealant PLEASE CONTACT YOUR DEEPWATER REPRESENTATIVE FOR A...

Page 5: ...he inside of the pressure housing is gained by pulling the lens Removing the lens in the field should be avoided wherever possible 4 1 3 Bulkhead connector The back end of the pressure housing is sealed with three bulkhead connectors These connectors thread into the back of the pressure housing and also seal with o rings It should not be necessary to remove these connectors during normal maintenan...

Page 6: ...C Meter 300 AD to the ROV frame and provide angled adjustment to optimize camera viewing of the displays The mount and all fixing hardware are made of Delrin 4 3 Flying leads 4 3 1 There are three leads supplied per kit each serving a unique function 4 3 2 A full wiring diagram can be found in section 6 0 Figure 4 Meter mount Figure 5 Flying leads ROV II meter side Female 3 pin EFG probe side Male...

Page 7: ...placeable contact tip it also includes the female connector that attaches to the male pin on the extension cable from the tail unit Tips are made from stainless steel and plated with nickel the nose cone is fabricated from a rugged thermoplastic 5 4 Reference electrode element Two plug in silver silver chloride elements are included Electrode elements are accurate to 5 mV See the operations and ma...

Page 8: ...he probe tip The upper two display lines on the LED readout should read between 1 030V and 1 070V and be within 0 005V of each other NOTE If the probe has not been used in the past 24 hours it may take 15 30 minutes for the probe to reach equilibrium EFG calibration check only applicable if using the EFG probe 7 2 4 Ensure both sets of holes on the EFG probe are submerged Ensure there is no trappe...

Page 9: ... 8 1 4 If using zoom cameras position the camera approximately 12 away from the edge of the lens 8 1 5 If using fixed zoom cameras physically position the camera approximately 0 5 to 3 away from the edge of the lens 8 1 6 Ensure that all fasteners are tightly secured and in good condition Verify that all lock nuts and washers are in place on the readout unit mount 8 1 7 Connect and route the power...

Page 10: ...f problems persist NEVER immerse the system with any connectors un mated unless the dummy plugs are installed 10 Data interpretation 10 1 For carbon steel structures in seawater the readings obtained should be within the ranges specified in Table 3 Exceptions may occur if the probe is stabbed onto an isolated section of a corrosion resistant alloy such as stainless steel copper or nickel In these ...

Page 11: ...ltmeter set on 2 00 VDC range stab the large pin socket pin 1 with the positive voltmeter lead and stab pin socket 2 first clockwise of large pin with the negative lead note reading Then repeat stabbing pin socket 3 with the negative lead and note the reading The faulty electrode will be the one that gives the lowest least negative reading 11 2 6 Ensure that the probe is drained of seawater 11 2 7...

Page 12: ...300 AD operation manual 12 SMB 001 Deep C Meter 300 AD Manual 12 RS232 Functions 12 1 Data output 12 1 1 Data string structure Stab 1 Stab 2 EFG For example 1034 1035 12 2 1034 1036 12 2 12 1 2 After each data set there is a line feed and carriage return present The rate is 2 data sets per second Table 4 RS232 communication settings Speed Baud 9600 Data bits 8 Stop bits 1 Parity None Flow control ...

Page 13: ...n real time Comma separator Command SD Tab separator Command SDHT Analog polarity command SP polarity Sets the polarity of analog voltages being measured by the ADC There is no response for this protocol Positive character sets the common analog ground to the negative side of the converter Positive Command SP Negative Command SP Online calibration Cal Re calibrates the internal AD which takes appr...

Page 14: ...flying lead is nicked Inspect and repair replace as necessary Displays are blank Whip is cut or power polarity is inverted Check cabling and wiring Displays are too dim or blurry Intensity is set too high or low for the available camera Increase intensity of light shining on meter Adjust the intensity using the command line See Table 5 RS232 Command List Garbled data stream output Ground fault or ...

Page 15: ...0009 Lens O ring 2 4 GSK0008 Lens backup ring 1 2 FAS0107 Lens retaining screw 4 1 MFR0016 Lens cover 1 0 UWC0038 Power bulkhead dummy plug female 1 0 UWC0044 EFG bulkhead dummy plug male 1 0 UWC0045 ROV II bulkhead dummy plug female 1 0 UWC0041 ROV II flying lead 1 0 UWC0035 Power cable whip 1 0 UWC0061 EFG flying lead Optional Optional MLT0042 EFG probe Optional Optional MLT0026 ROV II probe nos...

Page 16: ...manual 16 SMB 001 Deep C Meter 300 AD Manual Figure 7 Cell to Zn coupon ROV II calibration wiring schematic Calibration voltmeter display at 2 Volts DC setting Seawater solution Non metallic bucket Step VE VE DC scale Expected result 01 Tip Pin 1 Reference electrode 2 Pin 3 2 V 1 030 to 1 070 02 Tip Pin 1 Reference electrode 1 Pin 2 2 V 1 030 to 1 070 Zn calibration coupon Readings should be withi...

Reviews: