release lever R (14).
Keepthe lever depressed
throughout the following
procedure.
c
Hold the film holder in one
hand with the opening in the
film plane facing you. With
the thumb of the other hand,
gently push the film envelope
out as shown (15) until the
metal cap is visible. Then
grasp the end of the
envelope and pull it out. To
process the film, carefully
reinsert the envelope into the
film holder as when first
loading, move the control arm
to P, and process it as
described in section 12.
16 Changing the batteries
If the display or tone fades,
or if the timer stops
functioning, the batteries
should be replaced. The
timer uses either two 1.5 volt
SR-54 or two 1.5 volt LR-54
batteries. Slide battery cover
open (16) and the insert
batteries (17). Then replace
the cover. The timer will
display “545” for a few
seconds as shown.
Always re-enter the film timer
code and reset the Auto off
function after changing the
batteries. NOTE: It is
recommended that the SR-54
batteries are used as LR-54
batteries will require to be
replaced more often.
17 Cleaning the rollers
Dirt on the two steel
processing rollers can cause
repeated spots on the print
and poor colours. Check
regularly to see that the
rollers are clean and free of
foreign matter.
a
Move the control arm to L (?).
b
Grip the hinged roller cover
as shown (18) and pull
upward to open the cover.
c
Disengage the hooks (19) at
the ends of the rollers. The
top roller will swing up to
permit easy cleaning of the
entire assembly (20).
d
Clean the rollers with a soft,
lint free cloth, dampened with
water if necessary. Rotate
the rollers as you clean and
inspect them. Also clean
therubber light seal roller.
Never scrape the rollers with
anything metallic, nor with
your fingernail.
e
Replace the top roller,
engage the hooks, then snap
the cover closed.