11.69
NOTICE
If the regulator / rectifier case temperature exceeds
230° F or 110° C, the unit will turn itself off to cool down.
The unit will turn on again after it has cooled down to at
least 212° F or 100° C. If it turns off, verify the cooling
fins are clean, free from debris and that adequate
airflow is present.
BATTERY CONDUCTANCE ANALYZER
Conductance describes the ability of a battery to conduct
current. A conductance tester functions by sending a low
frequency AC signal through the battery and a portion of
the current response is captured, from this output a
conductance measurement is calculated. Conductance
testing is more accurate than voltage, specific gravity, or
load testing.
Authorized Polaris dealers/distributors are required to
use the conductance analyzer when testing 12V Polaris
batteries.