PLC (X-10) Devices
If a PLC (Power Line Carrier) Kit is installed
on the system, Eos can control lights, fans,
stereos, and other household appliances.
Devices plug into a small receiver that
plugs into a regular wall outlet inside the
house. The receiver communicates with
a transmitter connected to the Eos
Command Center.
Once set up, devices can be turned on or
off from the
Main
screen (Ex: Music is On)
just like any other device wired directly to the
Eos. Lamp dimmer modules also provide a
percentage setting for bright to dim lighting.
Select the folder next to the PLC device to
open the
PLC Device Manager
screen.
PLC devices can be scheduled like any other
piece of equipment.
Receiver modules can be added to the
system at any time. Contact your Polaris
dealer for information on PLC Receivers.
To add a PLC device:
1.
Scroll to the
Setup
screen on the
command center or remote display.
Move the curser to the Device Setup
folder and press <Enter> to open the
Device Setup
screen.
With the cursor over the X-10 Devices
folder, press <Enter> to open the
X-10 Setup
screen.
22
E
Device Setup
Scenes & Shortcuts
Owner Info
Polaris Info
Standby
Freeze Protection
Temperature
Fahrenheit
Date
Aug
03, 2004
Time 02:04pm
Left or right
arrow keys will
change screen
Setup
Tue, Aug 03 2:04 pm
To adjust display settings,
press and together.
Air 60° Water 60°
Configuration Combo
High Power HP1-HP8
Low Power LP1-LP6
Valves VLV1-VLV6
Sensors SNS1-5, PRES
Shortcut Remote
X-10 Devices
Reset Schedules
Reset System
Use left/right
arrow keys to
change screens.
Device Setup
Tue, Aug 03
2:04 pm
Use arrow keys to
move curser over
the folder icon.
Press <Enter> to
select and open
a new screen.
Press <Enter> to
activate or deactive
Check Box feature.
Pool Setpoint 78°
Spa Setpoint 103°
PS Heater
On
Circulation Mode Spa
Music
On
Cleaner Pump
Off
Pool Light
On
Spa Light Dim
60%
Suction Valve Off
Return Valve Off
Cleaner Valve Off
Spa Night
On
Main
Tue, Aug 03
2:04 pm
To adjust display settings,
press and together.
Current Temperature
Readings
Select folder icon
to open the Device
Manager screen.
Designated Heater
Temperture
Status Field indicates
status of device. Press
<Enter> to change.
Flame indicates
heater is firing
Adjustable settngs
available for device operation
Clock indicates device
is scheduled to be “On”
Air 60°
Water 71°
To adjust display settings,
press and together.
Day Start Stop
off 12:00p 12:00p
off 12:00p 12:00p
off 12:00p 12:00p
off 12:00p 12:00p
Duration Remaining
04h 00m 00h 00m
Manual Control
Schedules
Tue, Aug 03
2:04 pm
PLC Device Manager
M usic
Off
Air 60°
Water 71°
Save