E
17
After the heater shuts down, it enters a 2-minute cool down period.
Heater Cooling
Down
will be displayed on the screen. If the filter pump is shut down during the cool
down, the pump will remain on until the delay is finished and an hourglass will be
displayed next to the pump on the screen.
Cleaner Booster Pump
The pool cleaner will only activate when the system is in the pool mode (i.e., water
circulating to the pool) as it requires water circulation to function correctly.
Cleaner
Requires Pool Mode
is displayed if cleaner schedule requires circulation mode
adjustment.
There is a 1-minute prime delay to ensure the water is flowing to the booster pump.
The display will read
Prime Delay
during this delay.
If the filter pump is turned off while the cleaner booster pump is running, the
controller will automatically shut down the booster pump. The system recognizes that
the booster pump cannot run without the circulation pump.
If the booster pump cleaner is active and spa or spa spillover mode is entered the
booster pump will shut down and be locked-out. When the spa or spa spillover mode
is cancelled, the booster pump schedule will resume.
Spa Drain
The spa drain can only be activated on the Service screen.
Valves
Valves Turning
is displayed whenever a valve (pool to spa, spa to spillover, solar,
etc.) is signaled to rotate. There is a 15 second delay during which the filter pump is
shut off. The pump is reactivated when the valves have stopped turning.
Solar Heating Systems
When solar heating is initiated and there is a booster pump cleaner on the system,
the booster pump will shut down and be locked-out for a 2-minute
Solar Purge Delay
to allow water to be purged from the solar collectors. When the delay is complete, the
booster pump is reactivated.
When equipment is manually activated:
Existing schedules will be overridden. Remember to shut down the equipment, otherwise,
the equipment will continue to run until the next scheduled shut down or time-out
specified in the device setup.
If spa mode is not turned off, only the water in the spa will be filtered and the pool cleaner
will be disabled.
Turning off the filter pump does not reset valves to pool mode. The valves will
automatically return to pool mode after 6 hours.
Communication Failures
Communication failure messages (
CPC-ACT Comm Failure, X10 Comm Failure
, etc.)
are displayed when there is a communications failure between the command center and
the system components. Check connections or reposition the remote or antenna
and try again.