Personalized Automated Control System
Page 1: ...O w n e r s M a n u a l E Personalized Automated Control System ...
Page 2: ...t Always keep command center door closed when not accessing display panel Do not allow children to handle this product The Eos Wireless Remote requires a fully charged battery at startup Charge battery for at least 5 hours before use An inadequate charge can permanently damage the battery For customer service or support Please mail Warranty Card immediately For on line support www polarispool com ...
Page 3: ...n is complete Operates independently or can be remotely controlled from optional in house wired remotes wireless remotes or the Shortcut spa side remote Remotely operates electric devices including household appliances with the optional PLC Power Line Carrier Kit Controls optional sanitation equipment including traditional chemical or salt chlorination systems Command Center Open with Deadfront Re...
Page 4: ...the setting Item in reverse white text on black box indicates curser is over item or field Asterisk in front indicates a text field blank line that can be named by user Clock next to equipment status field means device is scheduled to be on Flame next to status field of heater means heater is firing Aug Aug 2 E System Overview Device Setup Scenes Shortcuts Owner Info Polaris Info Standby Freeze Pr...
Page 5: ...ble Main Screen Once setup is complete the Main screen provides access to most commonly needed measurements and functions Most routine maintenance and adjustments can be made from this screen E 3 Device Setup Scenes Shortcuts Owner Info Polaris Info Standby Freeze Protection Temperature Fahrenheit Date Aug 03 2004 Time 02 04pm Left or right arrow keys will change screen Setup Tue Aug 03 2 04 pm To...
Page 6: ...etting Using text fields 1 Move cursor over the text field and press Enter to select 2 Use the up down arrow keys to move through the alpha numeric options 3 Use the right arrow key to move to the next position within the field 4 Press Enter when the entry is complete Using nameable text fields 1 Move cursor over name field and press Enter to select The last letter of the name will blink 2 Use the...
Page 7: ...thin the Command Center that sounds when an alert condition exists If remote devices are used to control the Eos the alarm for each device can be enabled or disabled independently To set or adjust any of the display controls 1 Use arrow keys to move the cursor over the field to be adjusted Ex 2 Press Enter to select the item The item will flash 3 Use up arrow to increase or down arrow to decrease ...
Page 8: ...e 2 Press and hold Enter 3 Push the up or down arrow key to move the device To insert a space between menu items 1 Move the cursor to the Status field of the device you want to insert a line above 2 Press and hold Enter 3 Press the up and down arrow keys simultaneously A space will be inserted above the item To delete the space move the item back up Pool Circulation Pool PS Heater Off Pool Setpoin...
Page 9: ... keys to move the cursor over the hour field Ex first 2 Press Enter to select the item The item will flash 3 Use the up arrow to run through the setting options selecting the appropriate hour with am or pm 4 Press Enter to activate the setting 5 Use the same steps to set the minutes When adjustments are complete use the left or right arrow key to return to the Main screen Left or right arrow keys ...
Page 10: ... circulation mode Move the cursor over the circulation folder and press Enter to open the Device Manager screen Pool Configuration Circulation Mode Additional Settings Options With a Two Speed Pump Pool Spa with Shared Pump and Spillover Enabled Pool Spa Spill Off Pool LS Spa LS Spill LS Pool Spa with Shared Pump without Spillover Pool Spa Off Pool LS Spa LS Pool Only On Off On Low Off Spa Only On...
Page 11: ...er manual control Schedules Scheduling is available for each device Up to four schedules can be set based on date and time When scheduling equipment associations and manager rules should again be taken into consideration For detailed information on equipment review the original manufacturer s documentation or talk with a pool professional Day Specifies day s of operation Sun Mon Tue etc or All M F...
Page 12: ...ect The item will flash 2 Use the up down arrow keys to set the day Press Enter to activate the selection 3 Move cursor to Start hour field and press Enter to select Use the up down arrow keys to choose start time Press Enter to activate Set minutes if desired 4 Move cursor to Stop Set stop time hours and minutes 5 Move cursor to Mode select the circulation mode and press Enter to activate 6 Use t...
Page 13: ...ature gets within 5 degrees of the Solar Panel Temp Then solar heating will shut off and the other heater s if activated will continue to heat until the setpoint is reached Solar Panel Temp displays the current reading from the temperature sensor on the solar panel Use left right arrow keys to change screens Status of device Press Enter to change Select protectio and on Setup sc Tue Aug 03 2 04 pm...
Page 14: ...g In this example circulation mode is Spa Spa setpoint is 103 Pool Light is On Spa Light is dimmed to 60 and Music is On 2 Use the left arrow key to move to the Setup screen 3 Move cursor to the Scenes Shortcuts folder Press Enter to open the Scenes Shortcuts screen 4 Move the cursor to the first available text field under My Scenes 5 Press Enter to select the field and use the arrow keys to name ...
Page 15: ...together Day Start Stop off 12 00p 12 00p off 12 00p 12 00p off 12 00p 12 00p off 12 00p 12 00p Duration Remaining 04h 00m 00h 00m Manual Control Schedules Tue Aug 03 2 04 pm My Scene Manager Spa Night Off Save Air 60 Water 71 Pool Setpoint 78 Spa Setpoint 103 PS Heater On Circulation Mode Spa Cleaner Pump Off Pool Light On Spa Light Dim 60 Suction Valve Off Return Valve Off Cleaner Valve Off Musi...
Page 16: ...he device manager for the Shortcut can be accessed by selecting the folder next to it 14 E Setup Tue Aug 03 2 04 pm To adjust display settings press and together Air 60 Water 60 Hour is selected Device Setup Scenes Shortcuts Owner Info Polaris Info Standby Freeze Protection Temperature Fahrenheit Date Aug 03 2004 Time 02 04pm Scenes Shortcuts Tue Aug 03 2 04pm Air 60 Water 71 My Scenes 1 2 3 4 5 M...
Page 17: ...ked the heater will fire when the water temperature drops to 33 F During Freeze Alert In the pool spa combo and pool spa separate configurations the system will alternate between activating the spa and the pool equipment every 15 minutes In spa only and pool only configurations the equipment will alternate for 15 minutes on and 15 minutes off Blowers will run for five minutes every half hour No li...
Page 18: ...he desired temperature is reached the heater will turn off and remain off until the temperature falls two degrees below the setpoint This prevents the heater from short cycling i e turning on and off in rapid succession 16 E Alert Pool High Temperature Pool Low Temperature Spa High Temperature Spa Low Temperature Wireless Remote Battery Low WM 1 High PH Alert WM 1 Low PH Alert WM 1 High ORP Alert ...
Page 19: ... Drain The spa drain can only be activated on the Service screen Valves Valves Turning is displayed whenever a valve pool to spa spa to spillover solar etc is signaled to rotate There is a 15 second delay during which the filter pump is shut off The pump is reactivated when the valves have stopped turning Solar Heating Systems When solar heating is initiated and there is a booster pump cleaner on ...
Page 20: ...sure a full charge always store the remote on the charger when not in use An animated scrolling battery symbol on the display indicates the battery is charging Software Version provides access to current system software information Remote device settings including the unique remote channel setting are listed on the Network Settings screen Shutdown turns off the remote Useful to conserve battery li...
Page 21: ...out to switch the remote to sleep mode after a specified length of time without activity To save changes made to any settings on the Wireless Setup screen 1 Make adjustment then use the left arrow key to exit the screen A confirmation screen will open 2 Move curser to Yes and press Enter to activate the change To reset the wireless display if it is locked up or frozen 1 Press and hold Enter 2 Pres...
Page 22: ...set a time limit for inactivity after which the display turns off Hit any key to reactivate the display When Audible Alarm is checked the alarm in this remote device signals when an alert condition exists Access Code is a security feature available on the remote control devices When enabled system change capabilities are limited to authorized users If two In House Panels are installed on a system ...
Page 23: ...e device Temperature controls are the default on buttons A and B if a heater has been set up Temp Up and Temp Down button LEDs light only when the buttons are pushed Temp Up and Temp Down increase or decrease the temperature setpoint by one degree When the maximum temperature is reached 104 degrees for Spa the Temp Up button LED will stay lit To switch from Shortcut 1 functions to Shortcut 2 funct...
Page 24: ...e Setup folder and press Enter to open the Device Setup screen With the cursor over the X 10 Devices folder press Enter to open the X 10 Setup screen 22 E Device Setup Scenes Shortcuts Owner Info Polaris Info Standby Freeze Protection Temperature Fahrenheit Date Aug 03 2004 Time 02 04pm Left or right arrow keys will change screen Setup Tue Aug 03 2 04 pm To adjust display settings press and togeth...
Page 25: ...ow key to move to the next letter position within the field Press Enter when naming is complete 8 If a dimmer module is installed use the right arrow key to move to the dimmer Dim check box and press Enter to enable check dimming control for the device The dimmer control provides various settings between 0 100 to produce low to bright light levels ID Name Dim A01 Table Lamp A02 Music A03 A04 A05 A...
Page 26: ...press Enter to select the field 2 Enter the name in the text field using the up down keys to access the alpha numeric characters and the left right keys to move within the field Ex 3 Press Enter when naming is complete Refer to the Polaris Watermatic C2000 C2100 Owner s Manual for complete operation and maintenance information 24 E Tue Aug 03 2 04pm Watermatic 1 ORP 650 pH 7 5 Feeder Manual Status...
Page 27: ...current salt concentration or salinity of the pool is displayed in parts per million PPM Mode provides operational options Normal Chlorine production at normal rate Super Produces the maximum amount of chlorine for 24 hours then reverts back to normal mode If selected the pool pump must be activated for a 24 hour run cycle as well Service Disables control while chlorinator is being serviced Chlori...
Page 28: ...ettings From the Wireless Remote Setup screen select Network Settings Verify that the Eos SSID number is the antenna serial number located on left side of the antenna with three leading zeros and the second row of the Key number is the serial number with four leading zeros If two remotes are used with the antenna verify that each remote has its own unique Remote Address Ex first remote is set to 1...
Page 29: ...er cosmetic damage or damage due to acts of God water wind rain lightning freezing rodents or insects accident misuse abuse negligence or modification of or to any part of the Polaris Eos Control System This warranty does not cover consumables such as fuses or batteries These are normal replacement items Polaris will repair or replace at its option the System or part or component thereof proven to...
Page 30: ... the pool filtration equipment and the receiver Connect the equipment to an outlet on a different circuit from the one to which the receiver is connected This equipment has been certified to comply with the limits of a Class B computing device pursuant to FCC rules In order to maintain compliance with FCC regulations shielded cables must be used with this equipment Operation with non approved equi...