
46
CHECKING THE FIRING RATE
)ROORZWKHVHLQVWUXFWLRQVWRGHWHUPLQHWKHDFWXDO¿ULQJUDWHRIWKH
ZDWHUKHDWHU
NOTE:
7KH KHDWHUV FRYHUHG E\ WKLV PDQXDO DUH FDSDEOH RI
PRGXODWLQJWKHLU¿ULQJUDWH7KH¿ULQJUDWHVKRXOGEHFKHFNHGZLWK
WKHKHDWHURSHUDWLQJDWLWVIXOO¿ULQJUDWH
1.
(QVXUHWKHUHDUHQRRWKHUJDV¿UHGDSSOLDQFHVFRQQHFWHGWR
WKHJDVPHWHU¿ULQJGXULQJWKLVWHVW
2.
&RQWDFWWKHJDVVXSSOLHUWRGHWHUPLQHWKHKHDWLQJYDOXHLQ%WX
SHUFXELFIRRWRIWKHJDVVXSSO\
3.
&RQQHFWDPDQRPHWHUWRWKHVXSSO\JDVSUHVVXUHWDS)ROORZ
WKHLQVWUXFWLRQVIRU6WDUW8SEHJLQQLQJRQ3DJH
4.
6WDUWWKHZDWHUKHDWHUDQGHQVXUHLWLV¿ULQJ
5.
&KHFNWKHVXSSO\JDVSUHVVXUHUHIHUWR6XSSO\*DV6\VWHPV
RQSDJHIRUFRUUHFWSUHVVXUH
6.
/RFDWHWKHJDVPHWHUVHUYLQJWKHZDWHUKHDWHU
7.
7LPHKRZORQJLQVHFRQGVLWWDNHVIRURQHFXELFIRRWRIJDV
WREHXVHGZKLOHWKHZDWHUKHDWHULV¿ULQJZLWKDVWRSZDWFK
8.
8VHWKHIRUPXODEHORZWR³FORFN´WKHJDVPHWHUDQGGHWHUPLQH
WKHDFWXDO¿ULQJUDWHRIWKHZDWHUKHDWHUEDVHGRQWKHKHDWLQJ
YDOXH%WXSHUFXELFIRRWRIWKHJDVVXSSO\
x H = Btu/hr
3600
T
x 1050 = 300,000 Btu/hr (87.9 kW)
3600
12.6
Example:
•
VHFRQGVLQRQHKRXU
•
7 WLPHLQVHFRQGVWREXUQRQHFXELFIRRWRIJDV
•
+ KHDWLQJYDOXHRIJDVLQ%WXSHUFXELFIRRW
•
%WXKU DFWXDO¿ULQJUDWHRIWKHZDWHUKHDWHU
NOTE:
%WXSHUFXELFIRRWLVDVWDQGDUGYDOXHIRUQDWXUDOJDV
6WDQGDUGSURSDQHJDV%WXFRQWHQWLV%WXSHUFXELFIRRW%WX
YDOXHVPD\FKDQJHLQFHUWDLQDUHDVDQGDWKLJKHOHYDWLRQV&KHFN
ZLWKWKHORFDOJDVXWLOLW\FRPSDQ\
TO TURN OFF GAS SUPPLY
1.
&KDQJH WKH 2SHUDWLQJ 6HW 3RLQW WR WKH ORZHVW WHPSHUDWXUH
VHWWLQJ VHH 2SHUDWLQJ 6HW 3RLQW$QG 'LIIHUHQWLDO$GMXVWPHQW
on page 39.
2.
:KHQWKHZDWHUKHDWHUKDVFRPSOHWHGLWVVKXWGRZQVHTXHQFH
DQGHQWHUVWKHVWDQGE\PRGHWXUQWKHZDWHUKHDWHU¶V(QDEOH
'LVDEOHVZLWFKWRWKH³'LVDEOH´SRVLWLRQ:KHQLQWKH'LVDEOH
SRVLWLRQWKHVZLWFKRQO\UHPRYHVHOHFWULFDOSRZHUIURPWKHJDV
FRQWURO YDOYH VR WKDW ZDWHU KHDWLQJ LV GLVDEOHG 7KH GLVSOD\
&&% DQG RWKHU HOHFWULFDO FRPSRQHQWV ZLOO VWLOO EH HQHUJL]HG
DQGWKHGLVSOD\ZLOOUHDG:DWHU+HDWLQJ'LVDEOHG
3. Close Main Gas Shutoff Valve, see Figure 37 on page 31
GAS INPUT RATE
7KH JDV LQSXW UDWH RI WKLV ZDWHU KHDWHU LV DIIHFWHG E\ VHYHUDO
HQYLURQPHQWDOIDFWRUVVXFKDV
• The heating value of the gas
•
7KHDLUDQGJDVGHQVLWLHVZKLFKYDU\ZLGHO\GXHWREDURPHWULF
SUHVVXUHDQGWHPSHUDWXUHFKDQJHV
•
9HQWLQJLQVWDOODWLRQVSLSHGLDPHWHUOHQJWKDQG¿WWLQJV
•
$OWLWXGH
:KHQPHDVXULQJWKHLQSXWUDWHWKHVHIDFWRUVVKRXOGEHLQFRUSRUDWHG
LQWR WKH FDOFXODWLRQV $OVR PHDVXUH WKH JDV FRQVXPSWLRQ RYHU D
VXI¿FLHQWO\ ORQJ WLPH WR REWDLQ DQ DFFXUDWH JDV FRQVXPSWLRQ UDWH
HJPLQXWHVQRWRQHUHYROXWLRQRIWKHPHWHUQHHGOH
/RQJ YHQWV DQG HDFK DGGLWLRQDO HOERZ LQKHUHQWO\ UHGXFH WKH JDV
LQSXW UDWH GXH WR LQFUHDVHG UHVLVWDQFH WR PRYLQJ FRPEXVWLRQ DLU
DQG ÀXH JDVHV 7KH DSSUR[LPDWH PD[LPXPPLQLPXP LQSXW IRU DOO
PRGHOVVKRZQLQ)LJXUH
Figure 44
HIGH ALTITUDE INSTALLATIONS
Breathing Hazard - Carbon Monoxide Gas
•
Special consideration must be taken with
installations above 7,700 feet (2,347 m).
•
Please contact an A. O. Smith qualified
service agent to obtain the proper
setup and instructions before lighting.
•
Failure to implement the proper setup
will
result
in
improper
and
inefficient
operation of the appliance resulting in
production of increased levels of
carbon monoxide gas in excess of the
safe limits which could result in serious
personal injury or death.
Breathing carbon monoxide can cause brain damage or
death. Always read and understand instruction manual.
7KLV KLJK HI¿FLHQF\ ZDWHU KHDWHU LV FHUWL¿HG IRU XVH ZLWKRXW
PRGL¿FDWLRQ IRU DQ DOWLWXGH RI IHHW P &RQVXOW WKH
IDFWRU\IRULQVWDOODWLRQDWDOWLWXGHVRYHUIHHWP
6RPHJDVXWLOLW\FRPSDQLHVGHUDWHWKHLUJDVIRUDOWLWXGHPDNLQJLW
XQQHFHVVDU\ WR LQVWDOO KLJK DOWLWXGH RUL¿FHV &DOO WKH ORFDO JDV RU
XWLOLW\FRPSDQ\WRYHULI\%78FRQWHQW
'XHWRWKHLQSXWUDWHUHGXFWLRQDWKLJKDOWLWXGHVWKHRXWSXWUDWLQJRI
WKHZDWHUKHDWHULVDOVRUHGXFHGDQGVKRXOGEHFRPSHQVDWHGIRULQ
WKHVL]LQJRIWKHHTXLSPHQWIRUDSSOLFDWLRQV6HH3ODQQLQJWKH9HQW
System on Page 23.