14
Auto Close Timer
The amount of time between opening the gate and
automatically closing the gate can be adjusted between
15 seconds and 120 seconds. The adjustment is made
by turning the CLOSE TIMER potentiometer. The default
position of the potentiometer is zero seconds (gate will
close immediately once fully opened). To increase the
delay time, turn the potentiometer clockwise.
NOTE: The adjustment of the AUTO CLOSE
potentiometer will cause the bank of LED’s to temporarily
act as a meter.
NOTE: The Auto Close feature is only active if DIP switch
#2 is in the ON position.
For dual gates: the auto close timer in the primary
operator determines the setting for both gates.
Figure 14
WIRING AND HOOKUP INSTRUCTIONS
Auto close
potentiometer
Summary of Contents for SL2000