2. Wire Controller Display Description, Parameter Query and
Fault Table
2.1
Wire Controller Display Description
(
model
:
SHXK814
)
After the first power-on, the LCD screen displays the version number of the line controller for 2 seconds, and then the
full screen displays, and it enters the normal working state.
【
ON/OFF
】
In the boot state, press this key to enter the shutdown state, displaying water temperature, timing state and clock,
etc.
In the shutdown state, press this key to enter the boot state, displaying the operation mode, setting temperature,
water temperature, unit, timing state and clock, etc.
After the first power-on, if there is no key-press operation for more than 60 seconds, the controller automatically
enters the state of key-lock, and the
“
” symbol is displayed. Press this key for 3 seconds to release the lock key
status and the
“
”symbol disappears.
When setting clock, timing, parameter query and parameter setting, press this key to exit the setting state.
【
+
】【
-
】
This key can be used for parameter query, parameter setting, clock adjustment, timing adjustment and
temperature setting.
Press
【
+
】
to increase the temperature setting value and press
【
-
】
to decrease the temperature setting value.
【
Query/Time
】
Press this key to enter the clock setting state. The "HOUR" of the clock flickers. Adjust the "HOUR" by pressing
【
+
】
【
-
】
. P
ress
【
Query/Time
】
again to enter the "MINUTE" setting, the "MINUTE" of the clock flickers. Adjust the
"MINUTE" by pressing
【
+
】
【
-
】
, and then press
【
Query/Time
】
to confirm the clock setting and exit the clock setting.
Press this key to cancel the timed turn-on/turn-off in the setting state.
In the state of parameter query, pressing this key can clear the unrecoverable fault.