FROGGY

 

- Portable monitor, 750 lpm

FROGGY

 

- Portable monitor, 750 lpm

4

Warning

Warning

1 • Note

POK SAS reserves the right to change or modify the specifications of its products at any time to incorporate 

the latest technological and regulatory developments. The information contained in this document is subject 

to change without notice.

2 • General Warning

Before any use or installation of POK equipment, it is mandatory to read the information 

contained in this operating manual, to guarantee the safety of persons and material. 

The use, maintenance, or any other operation of the equipment, must be carried out 

exclusively  by  personnel  informed  of  safety  rules  and  trained  in  the  use  of  this 

material. 

The non-compliance of safety instructions can be dangerous and cause serious bodily 

harm and/or property damage.

3 • Safety

This symbol indicates important safety tips. Pay careful attention to prevent serious bodily 

harm and/or property damage.

 

This symbol indicates instructions that must be observed to ensure smooth operation of the 

device. Please always make sure to follow all the necessary precautions. 

This symbol indicates useful information to know and understand the correct operation of the 

device.

3.1 • General instructions 

Operators should read the operating instructions written in this manual before using the monitors. They shall 

not be used by people suffering from vision or hearing problems, illness or under medication. 

In order to work safely, please observe the following instructions while using the material:

• Material shall be used according to the instructions written by POK in this manual. 

• Systematically control the good condition of the monitors and the control systems before any use. 

• Any use not following the manual instructions could result in damages to people, to material or to 

environment. 

• Before opening of the water supply, check that every person (civil or from the brigade) is out of the aiming 

field of the monitor. Please be sure that the direction and the range of the stream cannot lead to potential 

material damages.

• Always know the hydraulic characteristics of the monitors.

• POK monitors have been designed to work with a POK outlet equipment (diffuser, branchpipe, blabbermouth, 

etc.). Never use an outlet equipment from another brand.

• Be sure that the outlet thread of the monitor fits with the one on the outlet equipment.

• Do not unnecessarily expose people to dangerous fire conditions.

• Always open the water supply valves of the monitor carefully, in order avoid any water hammer in the 

hoses.

• Never go over the indicated maximum flow rate and pressure, it could result in injuries to people and/or 

Summary of Contents for 04647

Page 1: ...Antoine Lavoisier 10400 Nogent sur Seine FRANCE Phone 33 0 3 25 39 84 78 Fax 33 0 3 25 39 84 90 Email export pok fire com Web www pok fire com MOP_LMM_02144_EN_A 13 03 2019 User manual Froggy Portable...

Page 2: ...50 lpm 2 Identification DESIGNATION DESCRIPTION Product type Monitor Product Portable monitor FROGGY 750 lpm made of aluminium alloy with shut off ball valve inlet 2 1 2 BSP male thread outlet 1 1 2 B...

Page 3: ...ability 6 5 Operational instructions 6 6 Warranty 6 7 Handling Transport Storage 7 TECHNICAL DATA 8 PRESENTATION 8 Main view 8 CHARACTERISTICS 9 Construction 9 General data 9 Pressure Loss Curve 10 DI...

Page 4: ...bol indicates useful information to know and understand the correct operation of the device 3 1 General instructions Operators should read the operating instructions written in this manual before usin...

Page 5: ...the monitor Never set the stream in a vertical position higher than 85 or lower than 35 The frost damages can be irreversible drain the monitor at low temperature near 0 C and below 3 3 Use An proper...

Page 6: ...or Please observe all local national and international instructions regarding property and persons safety accident prevention and environmental compliance Any non compliance with these instructions an...

Page 7: ...nical assessment The place of performance of the warranty is POK s plant in Nogent sur Seine 10 In the event of dispute regarding the supply or the payment of material only the commercial court of TRO...

Page 8: ...ta POK SAS can supply each product with different couplings Depending on your order the couplings can be different from the ones shown here MARK DESCRIPTION 1 Body made of aluminium alloy 2 Inlet flan...

Page 9: ...rews springs and axles Stainless steel Gaskets Nitrile Stabilizing legs pins Tungsten carbide Weight 6 1 Kg Construction DESIGNATION DESCRIPTION Flow rate 750 lpm 7 bar Maximum working pressure 16 bar...

Page 10: ...2144_EN_A 13 03 2019 Copyright POK SAS Illustrations are only informative FROGGY Portable monitor 750 lpm 10 Characteristics Technical data Pressure Loss Curve Kv change from 769 to 816 depending on d...

Page 11: ...port pok fire com Web www pok fire com FROGGY Portable monitor 750 lpm 11 MOP_LMM_02144_EN_A 13 03 2019 Copyright POK SAS Illustrations are only informative Dimensions Technical data Weight 6 1 Kg 469...

Page 12: ...n up to the CLIC Fig 1 2 Check that the stabilizing leg locking pin is locked Fig 2 3 Place the monitor on stable ground the four pins of the stabilizing legs in contact with the ground Fig 3 Note the...

Page 13: ...LMM_02144_EN_A 13 03 2019 Copyright POK SAS Illustrations are only informative Installation Instructions for use Connecting 1 Connect the diffuser or branchpipe not inclued with monitor on the outlet...

Page 14: ...ng solution Fig 9 depending on use 3 Supply the monitor with a suitable pump for the required flow rate Note To obtain optimal performance respect the following limits Maximum flow rate 750 l min Maxi...

Page 15: ...nformative Settings Instructions for use Adjusting the vertical position The monitor is adjustable in vertical position from 24 to 85 It is not recommended to use the monitor with a setting below 35 S...

Page 16: ...erial to water supply 3 Put a cap equipped with an air valve on the output of the monitor nozzles 4 Test the monitor while gradually increasing the pressure until reaching its nominal pressure Check f...

Page 17: ...ne FRANCE Phone 33 0 3 25 39 84 78 Fax 33 0 3 25 39 84 90 Email export pok fire com Web www pok fire com FROGGY Portable monitor 750 lpm 17 MOP_LMM_02144_EN_A 13 03 2019 Copyright POK SAS Illustration...

Page 18: ...1 LOWER AXLE SCREW 10518 14 2 STABILIZING LEGS AXLE 10876 15 12 SPRING WASHER 16644 16 1 LONG RIGHT STABILIZING LEG 17971 17 1 LONG LEFT STABILIZING LEG 17972 18 2 SPACER WASHER 10916 19 2 SHORT STABI...

Page 19: ...ogent sur Seine FRANCE Phone 33 0 3 25 39 84 78 Fax 33 0 3 25 39 84 90 Email export pok fire com Web www pok fire com FROGGY Portable monitor 750 lpm 19 MOP_LMM_02144_EN_A 13 03 2019 Copyright POK SAS...

Reviews: