POK 04647 User Manual Download Page 18

POK SAS - 18 Cours Antoine Lavoisier - 10400 Nogent-sur-Seine - FRANCE

Phone: +33 (0)3 25 39 84 78 - Fax: +33 (0)3 25 39 84 90 - Email: [email protected] - Web: www.pok-fire.com

MOP_LMM_02144_EN_A - 13/03/2019  - Cop

yright© POK S

A

S - Illustr

ations are only informativ

e

FROGGY

 

- Portable monitor, 750 lpm

FROGGY

 

- Portable monitor, 750 lpm

18

Parts list

Bill of materials

MARK

QTY

DESCRIPTION

CODE

1

1

BODY

18068

2

1

BALL

18069

3

1

SPACE TH.1

19552

4

1

CAP

18070

5

2

SPHERICAL PAD

18071

6

1

STREAM SHAPER

20021

7

1

BALL Ø52

2616

8

1

SQUARE FLANGE DN 65 - 2.5" BSP MALE

11920

9

1

VALVE AXLE

16188

10

1

FLAT HANDLE

14465

11

1

SCREW FOR VALVE AXLE

16189

12

1

LOWER AXLE

10517

13

1

LOWER AXLE SCREW

10518

14

2

STABILIZING LEGS AXLE

10876

15

12

SPRING WASHER

16644

16

1

LONG RIGHT STABILIZING LEG

17971

17

1

LONG LEFT STABILIZING LEG

17972

18

2

SPACER WASHER

10916

19

2

SHORT STABILIZING LEG

17973

20

1

BOTTOM PLATE

25671

21

4

PIN HOLDER

10867

22

1

LEGS LOCKING PIN SLEEVE

10901

23

1

LOCKING SPRING

10900

24

1

SAFETY PIN FOR STABILZING LEGS

10899

25

1

2 TURNS RING

2898

26

2

DRIVE PIN

20123

27

10

SCREW CHC M6-20

28

4

SCREW CHC M8-16

-

29

5

SCREW FHC M8-16

30

1

SCREW STHC TL M8-20

31

2

O’RING Ø64 x Ø4

-

32

2

GASKET FOR BALL Ø52

14800

33

2

O’RING R7

8207

34

2

O’RING N°12

8212

35

1

O'RING N°43

8243

36

1

O’RING R44

37

1

O’RING Ø117.07 X 3.53

16819

38

2

O’RING Ø101.2 X 3.53

39

4

PIN

10868

40

1

CARRYING HANDLE

10914

41

1

COVER FOR HANDLE

12021

42

1

SCREW CHC M10x35

-

43

1

WASHER W10

-

44

1

NUT H M10

Notes

Summary of Contents for 04647

Page 1: ...Antoine Lavoisier 10400 Nogent sur Seine FRANCE Phone 33 0 3 25 39 84 78 Fax 33 0 3 25 39 84 90 Email export pok fire com Web www pok fire com MOP_LMM_02144_EN_A 13 03 2019 User manual Froggy Portable...

Page 2: ...50 lpm 2 Identification DESIGNATION DESCRIPTION Product type Monitor Product Portable monitor FROGGY 750 lpm made of aluminium alloy with shut off ball valve inlet 2 1 2 BSP male thread outlet 1 1 2 B...

Page 3: ...ability 6 5 Operational instructions 6 6 Warranty 6 7 Handling Transport Storage 7 TECHNICAL DATA 8 PRESENTATION 8 Main view 8 CHARACTERISTICS 9 Construction 9 General data 9 Pressure Loss Curve 10 DI...

Page 4: ...bol indicates useful information to know and understand the correct operation of the device 3 1 General instructions Operators should read the operating instructions written in this manual before usin...

Page 5: ...the monitor Never set the stream in a vertical position higher than 85 or lower than 35 The frost damages can be irreversible drain the monitor at low temperature near 0 C and below 3 3 Use An proper...

Page 6: ...or Please observe all local national and international instructions regarding property and persons safety accident prevention and environmental compliance Any non compliance with these instructions an...

Page 7: ...nical assessment The place of performance of the warranty is POK s plant in Nogent sur Seine 10 In the event of dispute regarding the supply or the payment of material only the commercial court of TRO...

Page 8: ...ta POK SAS can supply each product with different couplings Depending on your order the couplings can be different from the ones shown here MARK DESCRIPTION 1 Body made of aluminium alloy 2 Inlet flan...

Page 9: ...rews springs and axles Stainless steel Gaskets Nitrile Stabilizing legs pins Tungsten carbide Weight 6 1 Kg Construction DESIGNATION DESCRIPTION Flow rate 750 lpm 7 bar Maximum working pressure 16 bar...

Page 10: ...2144_EN_A 13 03 2019 Copyright POK SAS Illustrations are only informative FROGGY Portable monitor 750 lpm 10 Characteristics Technical data Pressure Loss Curve Kv change from 769 to 816 depending on d...

Page 11: ...port pok fire com Web www pok fire com FROGGY Portable monitor 750 lpm 11 MOP_LMM_02144_EN_A 13 03 2019 Copyright POK SAS Illustrations are only informative Dimensions Technical data Weight 6 1 Kg 469...

Page 12: ...n up to the CLIC Fig 1 2 Check that the stabilizing leg locking pin is locked Fig 2 3 Place the monitor on stable ground the four pins of the stabilizing legs in contact with the ground Fig 3 Note the...

Page 13: ...LMM_02144_EN_A 13 03 2019 Copyright POK SAS Illustrations are only informative Installation Instructions for use Connecting 1 Connect the diffuser or branchpipe not inclued with monitor on the outlet...

Page 14: ...ng solution Fig 9 depending on use 3 Supply the monitor with a suitable pump for the required flow rate Note To obtain optimal performance respect the following limits Maximum flow rate 750 l min Maxi...

Page 15: ...nformative Settings Instructions for use Adjusting the vertical position The monitor is adjustable in vertical position from 24 to 85 It is not recommended to use the monitor with a setting below 35 S...

Page 16: ...erial to water supply 3 Put a cap equipped with an air valve on the output of the monitor nozzles 4 Test the monitor while gradually increasing the pressure until reaching its nominal pressure Check f...

Page 17: ...ne FRANCE Phone 33 0 3 25 39 84 78 Fax 33 0 3 25 39 84 90 Email export pok fire com Web www pok fire com FROGGY Portable monitor 750 lpm 17 MOP_LMM_02144_EN_A 13 03 2019 Copyright POK SAS Illustration...

Page 18: ...1 LOWER AXLE SCREW 10518 14 2 STABILIZING LEGS AXLE 10876 15 12 SPRING WASHER 16644 16 1 LONG RIGHT STABILIZING LEG 17971 17 1 LONG LEFT STABILIZING LEG 17972 18 2 SPACER WASHER 10916 19 2 SHORT STABI...

Page 19: ...ogent sur Seine FRANCE Phone 33 0 3 25 39 84 78 Fax 33 0 3 25 39 84 90 Email export pok fire com Web www pok fire com FROGGY Portable monitor 750 lpm 19 MOP_LMM_02144_EN_A 13 03 2019 Copyright POK SAS...