Point Grey Flea3 GigE Technical Reference
7 Image Acquisition
7.1.2
Standard External Trigger (Mode 0)
Trigger Mode 0 is best described as the standard external trigger mode. When the camera is put into Trigger Mode 0,
the camera starts integration of the incoming light from external trigger input falling/rising edge. The Exposure Time
describes integration time. No parameter is required. The camera can be triggered in this mode by using the GPIO pins
as external trigger or by using a software trigger.
It is not possible to trigger the camera at full frame rate using Trigger Mode 0; however, this is possible using
Overlapped Exposure Readout Trigger (Mode 14)
.
Figure 7.1: Trigger Mode 0 (“Standard External Trigger Mode”)
GenICam—
Acquisition Control
Acquisition Mode
Continuous
Trigger Selector
Exposure Start
Trigger Mode
On
Trigger Source
Line
x
(GPIO pin)
Trigger Activation
Rising or Falling edge
Trigger Delay
0
Exposure Mode
Timed
Exposure Time
Integration Time
Exposure Auto
Off
Registers—
TRIGGER_MODE: 830h
Presence
[0]
1
ON
[6]
1
Polarity
[7]
Low/High
Source
[8-10]
GPIO Pin
Value
[11]
Low/High
Mode
[12-15]
Trigger_Mode_0
Parameter
[20-31]
None
Revised 10/29/2013
Copyright ©2010-2013 Point Grey Research Inc.