PME miniPAR Logger User Manual Download Page 4

 
 
 

 

WWW.PME.COM 

TECHNICAL SUPPORT: [email protected] | (760) 727-0300 

PG. 4 

THIS DOCUMENT IS PROPRIETARY AND CONFIDENTIAL. © 2021 PRECISION MEASUREMENT ENGINEERING, INC. ALL RIGHTS RESERVED. 

 

I) 

The product has been altered or modified without PME’s written authorization,   

II)  the product has not 

been installed, operated, repaired, or maintained in accordance with PME’s 

instructions, including, where applicable, use of proper grounding to an earth ground source, 

III)  the product has been subjected to abnormal physical, thermal, electrical, or other stress, internal liquid 

contact, or misuse, neglect, or accident, 

IV)  the product failure occurs as a result of any cause not attributable to PME, 

V)  the product is installed with ancillary devices such as flow sensors, rain switches, or solar panels that 

are not listed as compatible with the product, 

VI)  the product is installed in a non-PME specified enclosure or with other incompatible equipment, 

VII) to address cosmetic issues such as scratches or surface discoloration, 

VIII) operation of the product in conditions other than that for which the product was designed, 

IX)  the product has been damaged due to events or conditions such as caused by lightning strikes, power 

surges, unconditioned power supplies, floods, earthquakes, hurricane, tornados, vermin such as ants 
or slugs or intentional damage, or 

X)  products provided by PME, but manufactured by a third-party company, which products are subject to 

the applicable warranty extended by their manufacturer, if any.  

There are no warranties that extend beyond the above limited warranty. In no event is PME 
responsible or liable to purchaser or otherwise for any indirect, incidental, special, 
exemplary, or consequential damages, including, but not limited to, lost profits, loss of data, 
loss of use, business interruption, loss of good will, or cost of procuring substitute products, 
arising out of or in relation to the product, even if advised of the possibility of such damages 
or losses. Some states do not allow the exclusion or limitation of incidental or consequential 
damages, so the above limitation or exclusion may not apply. This warranty gives you 
specific legal rights, and you may also have other rights which vary from state to state. 

W A R R A N T Y   C L A I M   P R O C E D U R E S  

A warranty claim must be initiated within the applicable warranty period by first contacting PME at 
[email protected] to obtain an RMA number. The purchaser is responsible for proper packaging and 
return shipment of the product to PME (including shipping expense and any related duties or other 
costs)

. The issued RMA number and purchaser’s contact information must be included with the 

returned product. PME is NOT liable for loss or damage of the product in return transit and 
recommends that the product be insured for its full replacement value. 

All warranty claims are subject to PME’s testing and examination of the product to determine if the 
warranty claim is valid. PME may also require additional documentation or information from the 
purchaser to evaluate the warranty claim. Products repaired or replaced under a valid warranty claim 
will be shipped back to the original purchaser (or its designated distributor) at PME

’s expense. If the 

warranty claim is found to be not valid for any reason, as determined by PME in its sole discretion, 
PME will notify the purchaser at the contact information provided by the purchaser. 

 

Summary of Contents for miniPAR Logger

Page 1: ...UPPORT INFO PME COM 760 727 0300 PG 1 THIS DOCUMENT IS PROPRIETARY AND CONFIDENTIAL 2021 PRECISION MEASUREMENT ENGINEERING INC ALL RIGHTS RESERVED 1483 POINSETTIA AVE STE 101 VISTA CA 92081 USA miniPA...

Page 2: ...ty 3 SAFETY INFORMATION 5 Bursting Hazard 5 CHAPTER 1 QUICK START 6 1 1 The Quickest Start Possible 6 1 2 A Few Details 8 CHAPTER 2 SOFTWARE 13 2 1 Overview and Software Installation 13 2 2 miniPARCon...

Page 3: ...excludes CT C sensors 1 year C Sense Logger Logger only 1 year For valid warranty claims made and covered defects existing during the applicable warranty period PME will at PME s option repair replac...

Page 4: ...sible or liable to purchaser or otherwise for any indirect incidental special exemplary or consequential damages including but not limited to lost profits loss of data loss of use business interruptio...

Page 5: ...come into contact with the enclosed batteries the batteries may generate gas causing the internal pressure to increase This gas will likely exit via the same location where the water entered but not...

Page 6: ...tion and PAR measurements together with a time stamp indicating the time the measurements were made are recorded in text files in the folder having the serial number of your miniPAR Logger These files...

Page 7: ...5 times The miniPAR Logger will now record a measurement of time battery voltage temperature PAR and 3 axis acceleration every 10 minutes or at some other interval you may have set using the miniPARC...

Page 8: ...tery voltage or to select a different recording interval miniPARControl will also update the time if the logger has drifted in time 8 Optional Run the miniPARPlot program to see a plot of measurements...

Page 9: ...occasionally to a HOST computer having an Internet connection The miniPARControl program will automatically set time based on an Internet time server Please refer to Chapter 2 for instructions on oper...

Page 10: ...teries AA LITHIUM BATTERY LIFE The miniPAR Logger consumes battery power mostly from the measurement of PAR and temperature but also a small amount from simply keeping track of time writing files slee...

Page 11: ...ry may leak Err on the side of caution when planning your deployment The recommended battery is the Energizer L91 lithium battery For more information including the performance at low temperatures cli...

Page 12: ...intervals of 1 minute or less 5 Green Flashes Normal Indicates that miniPAR Logger is beginning to record measurements This indication appears in response to switching the Logger Control Switch to Re...

Page 13: ...miniPARConcatenate jar program gathers all the daily files into one CAT txt file Manual pdf is the manual These files are located on the root directory of the miniPAR Logger PME suggests you leave the...

Page 14: ...al button To set the interval enter an interval not less than 1 minute and not greater than 60 minutes Click the Set Sample Interval button Shorter and faster intervals are available Contact PME If th...

Page 15: ...e scrolled with the mouse while the Control key is held depressed Copies of the plot can be obtained by right clicking on the plot and selecting Copy from the pop up menu Different DATA Folders can be...

Page 16: ...contains the files recorded by the miniPAR Logger If the miniPARPlot program is run directly from the miniPAR Logger the program will suggest the folder located on the miniPAR Logger You may accept t...

Page 17: ...g this procedure after being sure that the o ring is free from debris If debris is found then wipe it off with a clean lint free cloth PME recommends Kimtech Kimwipes for this application Lubricate th...

Page 18: ...s or Duracell AA size alkaline batteries http data energizer com PDFs l91 pdf http ww2 duracell com media en US pdf gtcl Product_Data_Sheet NA_DATASHEETS MN1500_US_CT pdf Caution Improper replacement...