background image

 
 
 

 

WWW.PME.COM 

TECHNICAL SUPPORT: [email protected] | (760) 727-0300 

PG. 17 

THIS DOCUMENT IS PROPRIETARY AND CONFIDENTIAL. © 2021 PRECISION MEASUREMENT ENGINEERING, INC. ALL RIGHTS RESERVED. 

 

CHAPTER 3: MINIPAR LOGGER 

3.1 Overview 

All miniPAR Logger measurements are saved in files on the SD card inside the miniPAR Logger. 
The files are transferred to a HOST computer via a USB connection where the miniPAR Logger 
appears as a “thumb drive”. Measurements may be plotted by the miniPARPlot program and files 
concatenated by the miniPARConcatenate program. The miniPAR Logger itself is controlled by the 
miniPARControl program. Customers are required to open the logger each time measurements are 
transferred to the HOST computer. This 

chapter describes the miniPAR Logger’s internal features. 

3.2 Opening and Closing the miniPAR Logger 

The miniPAR Logger’s circuitry is contained in a waterproof housing that must be opened.

 

Unscrewing the white pressure housing from the black end cap opens the miniPAR Logger.

 

This is 

similar to opening a flashlight. Turn the white pressure housing counterclockwise

 

relative to the black 

end cap. Close the miniPAR Logger by reversing this procedure after

 

being sure that the o-ring is 

free from debris. If debris is found, then wipe it off with a clean,

 

lint-free cloth. PME recommends 

Kimtech Kimwipes for this application. Lubricate the o-ring

 

occasionally with silicone oil intended for 

buna-N o-ring material. 

When closing the miniPAR Logger, inspect the o-ring and the interior of the white pressure

 

housing 

for debris. Lubricate the o-ring, and screw the white pressure housing onto the black

 

end cap until 

the white pressure housing just touches the black end cap. Do not tighten!

 

The miniPAR Logger 

tends to get a little tighter during deployment.

  

If you cannot open the miniPAR Logger by yourself, then find another person with strong

 

hands. This 

person should grip the black end cap while the other person turns the white

 

pressure housing. 

3.3 Electrical Connections and Controls

 

Removal of the cover reveals the miniPAR 

Logger’s 

connections and controls, shown here. 

The 

LED Light 

is a LED that can display either red or 

green light. This is used to indicate the different features 
described in Chapter 1 of this manual. 

The 

Logger Control Switch 

controls the miniPAR 

Logger’s mode: 

 

R

ECORD

:

 

When the switch is in this position the 

miniPAR Logger is recording measurements. 

 

H

ALT

:

 

When the switch is in this position the miniPAR 

Logger is not recording and is sleeping at low power. 

Summary of Contents for miniPAR Logger

Page 1: ...UPPORT INFO PME COM 760 727 0300 PG 1 THIS DOCUMENT IS PROPRIETARY AND CONFIDENTIAL 2021 PRECISION MEASUREMENT ENGINEERING INC ALL RIGHTS RESERVED 1483 POINSETTIA AVE STE 101 VISTA CA 92081 USA miniPA...

Page 2: ...ty 3 SAFETY INFORMATION 5 Bursting Hazard 5 CHAPTER 1 QUICK START 6 1 1 The Quickest Start Possible 6 1 2 A Few Details 8 CHAPTER 2 SOFTWARE 13 2 1 Overview and Software Installation 13 2 2 miniPARCon...

Page 3: ...excludes CT C sensors 1 year C Sense Logger Logger only 1 year For valid warranty claims made and covered defects existing during the applicable warranty period PME will at PME s option repair replac...

Page 4: ...sible or liable to purchaser or otherwise for any indirect incidental special exemplary or consequential damages including but not limited to lost profits loss of data loss of use business interruptio...

Page 5: ...come into contact with the enclosed batteries the batteries may generate gas causing the internal pressure to increase This gas will likely exit via the same location where the water entered but not...

Page 6: ...tion and PAR measurements together with a time stamp indicating the time the measurements were made are recorded in text files in the folder having the serial number of your miniPAR Logger These files...

Page 7: ...5 times The miniPAR Logger will now record a measurement of time battery voltage temperature PAR and 3 axis acceleration every 10 minutes or at some other interval you may have set using the miniPARC...

Page 8: ...tery voltage or to select a different recording interval miniPARControl will also update the time if the logger has drifted in time 8 Optional Run the miniPARPlot program to see a plot of measurements...

Page 9: ...occasionally to a HOST computer having an Internet connection The miniPARControl program will automatically set time based on an Internet time server Please refer to Chapter 2 for instructions on oper...

Page 10: ...teries AA LITHIUM BATTERY LIFE The miniPAR Logger consumes battery power mostly from the measurement of PAR and temperature but also a small amount from simply keeping track of time writing files slee...

Page 11: ...ry may leak Err on the side of caution when planning your deployment The recommended battery is the Energizer L91 lithium battery For more information including the performance at low temperatures cli...

Page 12: ...intervals of 1 minute or less 5 Green Flashes Normal Indicates that miniPAR Logger is beginning to record measurements This indication appears in response to switching the Logger Control Switch to Re...

Page 13: ...miniPARConcatenate jar program gathers all the daily files into one CAT txt file Manual pdf is the manual These files are located on the root directory of the miniPAR Logger PME suggests you leave the...

Page 14: ...al button To set the interval enter an interval not less than 1 minute and not greater than 60 minutes Click the Set Sample Interval button Shorter and faster intervals are available Contact PME If th...

Page 15: ...e scrolled with the mouse while the Control key is held depressed Copies of the plot can be obtained by right clicking on the plot and selecting Copy from the pop up menu Different DATA Folders can be...

Page 16: ...contains the files recorded by the miniPAR Logger If the miniPARPlot program is run directly from the miniPAR Logger the program will suggest the folder located on the miniPAR Logger You may accept t...

Page 17: ...g this procedure after being sure that the o ring is free from debris If debris is found then wipe it off with a clean lint free cloth PME recommends Kimtech Kimwipes for this application Lubricate th...

Page 18: ...s or Duracell AA size alkaline batteries http data energizer com PDFs l91 pdf http ww2 duracell com media en US pdf gtcl Product_Data_Sheet NA_DATASHEETS MN1500_US_CT pdf Caution Improper replacement...

Reviews: