background image

 
 
 

 

WWW.PME.COM 

TECHNICAL SUPPORT: [email protected] | (760) 727-0300 

PG. 3 

THIS DOCUMENT IS PROPRIETARY AND CONFIDENTIAL. © 2021 PRECISION MEASUREMENT ENGINEERING, INC. ALL RIGHTS RESERVED. 

 

WARRANTY 

Limited Warranty 

Precision Measurement Engineering, Inc. (“PME”) warrants the following products to be, as of the 
time of shipment, free from defects in materials or workmanship under normal use and conditions for 
the period indicated below corresponding to the product. The warranty period commences on the 
original date of purchase of the product. 

Product 

Warranty Period 

Aquasend Beacon 

1 year 

miniDOT Logger 

1 year 

miniDOT Clear Logger 

1 year 

miniWIPER 

1 year 

miniPAR Logger (Logger only) 

1 year 

Cyclops-7 Logger (Logger only) 

1 year 

C-FLUOR Logger (Logger only) 

1 year 

T-Chain 

1 year 

MSCTI (excludes CT/C-sensors) 

1 year 

C-Sense Logger (Logger only) 

1 year 

 

For valid warranty claims made and covered defects existing during the applicable warranty period, 
PME will, at PME’s option, repair, replace (with the same or then most similar product) or repurchase 
(at purchaser’s original purchase price), the defective product. This warranty extends solely to the 
original end-user purchaser of the product. 

PME’s entire liability and the sole and exclusive remedy 

for product defects is limited to such repair, replacement or repurchase in accordance with this 
warranty. 

This warranty is provided in lieu of all other warranties express or implied, 

including, but not limited to warranties of fitness for a particular purpose and warranties of 
merchantability.

 No agent, representative, or other third party has any authority to waive or alter 

this warranty in any way on behalf of PME.   

W A R R A N T Y   E X C L U S I O N S  

The warranty does not apply in any of the following circumstances:  

Summary of Contents for miniPAR Logger

Page 1: ...UPPORT INFO PME COM 760 727 0300 PG 1 THIS DOCUMENT IS PROPRIETARY AND CONFIDENTIAL 2021 PRECISION MEASUREMENT ENGINEERING INC ALL RIGHTS RESERVED 1483 POINSETTIA AVE STE 101 VISTA CA 92081 USA miniPA...

Page 2: ...ty 3 SAFETY INFORMATION 5 Bursting Hazard 5 CHAPTER 1 QUICK START 6 1 1 The Quickest Start Possible 6 1 2 A Few Details 8 CHAPTER 2 SOFTWARE 13 2 1 Overview and Software Installation 13 2 2 miniPARCon...

Page 3: ...excludes CT C sensors 1 year C Sense Logger Logger only 1 year For valid warranty claims made and covered defects existing during the applicable warranty period PME will at PME s option repair replac...

Page 4: ...sible or liable to purchaser or otherwise for any indirect incidental special exemplary or consequential damages including but not limited to lost profits loss of data loss of use business interruptio...

Page 5: ...come into contact with the enclosed batteries the batteries may generate gas causing the internal pressure to increase This gas will likely exit via the same location where the water entered but not...

Page 6: ...tion and PAR measurements together with a time stamp indicating the time the measurements were made are recorded in text files in the folder having the serial number of your miniPAR Logger These files...

Page 7: ...5 times The miniPAR Logger will now record a measurement of time battery voltage temperature PAR and 3 axis acceleration every 10 minutes or at some other interval you may have set using the miniPARC...

Page 8: ...tery voltage or to select a different recording interval miniPARControl will also update the time if the logger has drifted in time 8 Optional Run the miniPARPlot program to see a plot of measurements...

Page 9: ...occasionally to a HOST computer having an Internet connection The miniPARControl program will automatically set time based on an Internet time server Please refer to Chapter 2 for instructions on oper...

Page 10: ...teries AA LITHIUM BATTERY LIFE The miniPAR Logger consumes battery power mostly from the measurement of PAR and temperature but also a small amount from simply keeping track of time writing files slee...

Page 11: ...ry may leak Err on the side of caution when planning your deployment The recommended battery is the Energizer L91 lithium battery For more information including the performance at low temperatures cli...

Page 12: ...intervals of 1 minute or less 5 Green Flashes Normal Indicates that miniPAR Logger is beginning to record measurements This indication appears in response to switching the Logger Control Switch to Re...

Page 13: ...miniPARConcatenate jar program gathers all the daily files into one CAT txt file Manual pdf is the manual These files are located on the root directory of the miniPAR Logger PME suggests you leave the...

Page 14: ...al button To set the interval enter an interval not less than 1 minute and not greater than 60 minutes Click the Set Sample Interval button Shorter and faster intervals are available Contact PME If th...

Page 15: ...e scrolled with the mouse while the Control key is held depressed Copies of the plot can be obtained by right clicking on the plot and selecting Copy from the pop up menu Different DATA Folders can be...

Page 16: ...contains the files recorded by the miniPAR Logger If the miniPARPlot program is run directly from the miniPAR Logger the program will suggest the folder located on the miniPAR Logger You may accept t...

Page 17: ...g this procedure after being sure that the o ring is free from debris If debris is found then wipe it off with a clean lint free cloth PME recommends Kimtech Kimwipes for this application Lubricate th...

Page 18: ...s or Duracell AA size alkaline batteries http data energizer com PDFs l91 pdf http ww2 duracell com media en US pdf gtcl Product_Data_Sheet NA_DATASHEETS MN1500_US_CT pdf Caution Improper replacement...