12
Technical data
INPUTS
SIGNAL INPUT INP
Accuracy:
0,01% at 25°C
Decimal point:
0 bis 3 decimals
Input filter:
adjustable 0.0...999.9 s
Scanning cycle:
50 ms with 19 bit
Linearization:
31 Segments, adaptable with
BlueControl
®
Calibration:
with/without shunt calibration
Measurement value cor-
rection:
2-point
Limiting frequency
1.7Hz
Measurement value cor-
rection:
Sensor break, short circuit and po-
larity
Connection technology:
4-wire bridge
6-wire bridge (Sense line)
Input range
Span start, span end
any, within measuring range
Scaling
any, -1999 ...9999
Measurement span:
with Us = 10V
Slope/ sensitivity
0.5 mV/V
5 mV
1 mV/V
10 mV
2 mV/V
20 mV
4 mV/V
40 mV
DIGITALINPUT DI1
Operation as
Contact input
Connection of a potential-free contact that is suitable for
switching ‘dry’ circuits.
Switched voltage:
5 V
Current:
0.5 mA
Function
Configurable as direct or inverse switch or
push button
!
Functions:
Operation disabling, reset of stored alarms and the
min/max indicator (slave pointer), the integrator,
enabling the tare function,Sample&Hold amplifier
function, Cal-Test , and zero setting.
OUTPUTS
RELAY OUTPUTS OUT1, OUT2
Contact type:
2 normally open with common
contact connection
Max. contact rating:
500 VA, max. 250 V, max. 2A
at 48...62 Hz, ohmic load
Min. contact rating:
6V, 1 mA DC
Swithing cycles (electrical):
for I=1A/2A:
?
800,000/500,000 (at~250V
(ohmic load))
Note:
If the relays OUT1, 2 and 3 are used to operate external contac-
tors, these must be fitted with RC snubber circuits to manufactu-
rer specifications to prevent excessive voltage peaks at
switch-off.
OUT3 AS UNIVERSAL OUTPUT
Parallel current/voltage output with common ‘minus’ terminal
(combined use only in galvanically isolated circuits).
Freely scalable
Resolution:
14 Bit
Dynamic response
(step change of input signal) T
90
:
Output follows the in-
put within 300 ms
Tracking error I/U:
Residual ripple:
(rel. to range end)
£
2 %
ß_
1%
0...130 kHz
Current output
0/4...20 mA, configurable, short-circuit proof.
Control range:
-0.5....23 mA
Load:
£
600
[
Load effect:
ß
0.02%
Resolution:
ß
1.5
ú
A
Error:
ß
0.1%
Voltage output
0/2...10V, configurable, not permanently short-circuit proof
Control range:
0.15...11.5 V
Load:
?
2 k
[
Load effect:
ß
0.06%
Resolution:
ß
0.75 mV
Error:
Additional error when using simultaneous-
ly the current output
ß
0.1%
ß
+0.09%
Output values can be preset via interface (Forcing)
Technical data
UNIFLEX SG 45