7
Calibration level
g
Measured value correction
(
CAL
)
is only visible if
ConF
/
InP.1
/
Corr
=
1
or
2
is chosen.
The measured value can be matched in the calibration menu (
CAL
). Two me-
thods are available:
7.1
Offset correction
(
ConF
/
InP.1
/
Corr
=
1
):
possible on-line at the process
2-point correction
(
ConF
/
InP.1
/
Corr
=
2
):
w
is possible off-line with process
value simulator
w
online in 2 Schritten zunächst
den einen Wert korrigieren und
später, z.B. nach dem Aufheizen
des Ofens, den zweiten Wert
korrigieren.
Calibration level
Digital 280-1
Offset correction
37
X
standard-setting
Offset-correction
InL
OuL
new
display
OuL
old
X
Standardeinstellung
2-Punkt-Korrektur
InL
InH
OuL
neu
OuH
neu
Display
OuH
alt
OuL
alt