DES-P Digital Engine Supervisor 

 
 

Cat_DES-P-09-GSM new Ver 2.0 
  

Page 

8/9 

 

10.3

 

Fault Reset 

All internal faults can be reset by pressing (R)  switch after the generator is stopped.  In case the 
engine fails to stop “STOP KEY” can be pressed for manual attempt to stop engine. 
 

11.0

 

Terminal description 

Terminal Number  

Description 

1 Not 

Connected 

2 Not 

Connected

3 Not 

Connected

4 Not 

Connected

5 LLOP 

Sensor 

6 HWT 

Sensor 

 

7 Fuel 

Sensor 

8 RWL 

 

Charging Alternator Input 

10 

Auxiliary ve     

11 

Auxiliary supply -ve     

12 

Crank NO Contact    

13 

Solenoid NO Contact   

14 

Charging Alternator  On 

15 Hooter 
16 

Common for All Contacts 

17 Remote 

Start 

18 

Remote Stop  

19 Not 

Connected

 

20 Not 

Connected

21 Not 

Connected

22 Not 

Connected

23 Not 

Connected

24 Not 

Connected

 

12.0

 

Model Selection 

The nomenclature for selecting the model is as follows: 
DES-P 
 
 
 

 

13.0

 

Specifications  

ƒ

 

Surge 1.2/50Usec 

 

 

2.5KV 

ƒ

 

Battery Voltage 

 

 

Suitable for 12V/24 VDC System 

ƒ

 

Min. voltage to power on  

 

9V 

ƒ

 

Min Running Voltage after Power on 

4V 

ƒ

 

Max. Battery Voltage 

 

 

35V 

ƒ

 

DC Interruption time 

 

 

1 Sec. 

ƒ

 

Digital Output            

 

 

+ 12V 

ƒ

 

Cut out Dimensions 

 

 

92mm X 92mm 

ƒ

 

Depth    120mm 

 

ƒ

 

Digital Input Level 

 

 

Battery –Ve  except Charging Alt, which is 

b Ve 

 
 
 
 
 

Summary of Contents for Procom DES-P

Page 1: ...organization Works Unit1 E 41 5 Okhla Industrial Area Phase II New Delhi 110020 Unit2 T 13 Okhla Industrial Area Phase II New Delhi 110020 Ph 011 30883538 41 9810344265 9310883837 Fax 0 1130883536 Em...

Page 2: ...DES P Digital Engine Supervisor Cat_DES P 09 GSM new Ver 2 0 Page 2 9...

Page 3: ...nnunciations 5 0 Contacts 6 0 Timers 7 0 Switches Description 8 0 Operation 9 0 Setting Procedure 9 1 Parameter Settings 9 2 Fault History Viewing 9 3 Service Hour Resetting 9 4 Programming Solenoid M...

Page 4: ...acts for system stability and reliability All contacts are protected by TVS to strengthen the EMI EMC capabilities of the unit Housed in 92X92mm Din Standard housing 2 0 Protection Supervision Salient...

Page 5: ...f 1 Sec shall reset both 5 R Programming Mode Entry Press R Key and than press while the R Key is pressed to enter the programming mode 8 0 Operation DES P is an engine monitoring and supervisor unit...

Page 6: ...sure switch and not through the oil pressure sensor linear measurement All sensors All sensors Fuel HWT Fuel LLOP LLOP HWT Fuel Only HWT Only LLOP Only No sensor 7 Fuel Level in Level of fuel at which...

Page 7: ...Service Hours Service due warning is issued by DES P by flashing the Ser LED This LED shall keep flashing till it is not reset by entering this mode Pls refer Para 9 for procedure to reset service hou...

Page 8: ...1 Auxiliary supply ve 12 Crank NO Contact 13 Solenoid NO Contact 14 Charging Alternator On 15 Hooter 16 Common for All Contacts 17 Remote Start 18 Remote Stop 19 Not Connected 20 Not Connected 21 Not...

Page 9: ...8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 Not Connected Not Connected Not Connected Not Connected Oil Pressure Sensor Switch Water Temp Sensor Switch Low Fuel Sensor Switch RWL Switch Ch Alt Ve W...

Reviews: